ئىنگىلىزچە


Afrikaans
Albanian
Amharic
Arabic
Armenian
Azerbaijani
Basque
Belarusian
Bengali
Bosnian
Bulgarian
Catalan
Cebuano
China
China (Taiwan)
Corsican
Croatian
Czech
Danish
Dutch
English
Esperanto
Estonian
Finnish
French
Frisian
Galician
Georgian
German
Greek
Gujarati
Haitian Creole
hausa
hawaiian
Hebrew
Hindi
Miao
Hungarian
Icelandic
igbo
Indonesian
irish
Italian
Japanese
Javanese
Kannada
kazakh
Khmer
Rwandese
Korean
Kurdish
Kyrgyz
Lao
Latin
Latvian
Lithuanian
Luxembourgish
Macedonian
Malgashi
Malay
Malayalam
Maltese
Maori
Marathi
Mongolian
Myanmar
Nepali
Norwegian
Norwegian
Occitan
Pashto
Persian
Polish
Portuguese
Punjabi
Romanian
Russian
Samoan
Scottish Gaelic
Serbian
Sesotho
Shona
Sindhi
Sinhala
Slovak
Slovenian
Somali
Spanish
Sundanese
Swahili
Swedish
Tagalog
Tajik
Tamil
Tatar
Telugu
Thai
Turkish
Turkmen
Ukrainian
Urdu
Uighur
Uzbek
Vietnamese
Welsh
Bantu
Yiddish
Yoruba
Zulu TRANSFORMER OIL TESTING · PRODUCT GUIDE
When a transformer oil testing program calls for water-soluble acid determination, laboratories need equipment that fits the specified method and their daily sample workload. Understanding the measurement range, sample capacity, and automated functions helps buyers compare configurations more effectively.
The PS-3003 automatic water-soluble acid tester from باۋدىڭ ئىتتىرىش ئېلېكتر ئىشلەپچىقىرىش چەكلىك شىركىتى. combines a three-cup design with programmed testing functions, result storage, and USB communication. It is intended to support a structured laboratory workflow for this specific oil test.

The supplied product documentation identifies GB/T 7598-2008 as the design reference. This standard concerns the determination of water-soluble acid in transformer oils in service. The instrument specifies a pH measurement range of 3.6–7.0.
Before choosing equipment, confirm that water-soluble acid determination is the test required by your laboratory or customer. A pH-based result should not be presented as an oil acid-number result in mg KOH/g. Keep the test name, method, and reporting units together when preparing specifications or reviewing results.
The PS-3003 documentation states that one to three samples can be measured at one time. This configuration gives laboratories an option for organizing several samples within a testing run. Actual daily throughput should be assessed using the complete workflow, including sample preparation and cleaning.
Listed functions include automatic heating, constant-temperature control, oscillation, sampling, testing, cleaning, and printing. The instrument also provides direct-test and standard-test program options. Operators should select the appropriate program according to the required procedure rather than assuming the options are interchangeable.
A large LCD and microprocessor control provide the operator interface. A USB interface is available for communication with a computer. Buyers with specific data-transfer requirements should confirm the supplied software, file formats, and computer compatibility before ordering.
The documentation lists storage for 100 sets of data and automatic preservation of test results during a power interruption. It also describes a selectable pipeline-cleaning function. These features should be considered alongside the laboratory’s requirements for sample identification, record retention, and cleaning procedures.
| پارامېتىر | Specification |
|---|---|
| Model | PS-3003 |
| Product type | Automatic water-soluble acid tester |
| Measurement range | pH 3.6–7.0 |
| Minimum display increment | 0.1 pH |
| Measurement error | Within ±0.1 pH |
| Constant-temperature precision | ±2 °C |
| Sample capacity | 1–3 samples per run; integrated three-cup design |
| سانلىق مەلۇمات ساقلاش | 100 sets of data |
| Computer communication | USB interface |
| Ambient operating temperature | 5–45 °C |
| نىسپىي نەملىك | ≤85% |
| توك بىلەن تەمىنلەش | AC 220 V ±10%, 50 Hz ±1 Hz |
| Design reference stated in the documentation | GB/T 7598-2008 |
Specifications are based on the supplied PS-3003 product documentation. The standard reference is not a claim of third-party certification.
Start with the required test method, sample type, and expected daily sample quantity. Then check that the stated measurement range and operating conditions match your laboratory’s needs.
The provided specification sheet does not state a heating setpoint or complete sample preparation procedure. Operators should use the full operating instructions for these details rather than deriving them from the ambient temperature range or constant-temperature precision.
The supplied documentation specifies one to three samples at one time using its integrated three-cup design.
No. The minimum display increment is 0.1 pH, while the stated measurement error is within ±0.1 pH. These are separate specifications even though their numerical values are similar.
No. It is the stated ambient operating temperature range. The constant-temperature precision is listed separately as ±2 °C. Neither value establishes the test heating setpoint.
Yes. The documentation specifies a USB communication interface. Confirm the accompanying software and supported data workflow for your intended use.
ئالاقىلىشىڭ باۋدىڭ ئىتتىرىش ئېلېكتر ئىشلەپچىقىرىش چەكلىك شىركىتى. with your required test method, sample workload, power supply, and reporting preferences to discuss the PS-3003 configuration for your laboratory.