EnglishSaesneg

PUSH electricalPS-C2000A insulating oil dielectric loss and volume resistivity tester

PS-C2000A Insulating oil dielectric loss tester /Oil tan delta tester is new generation of fully automatic portable insulating oil dielectric loss and resistivity meter designed according to ASTM D924 and GB/5654.7-inch color touch screen It is used for measuring dielectric dissipation factor and DC resistivity of insulating oil and other insulating liquids. It is easy to operate with reliable and accurate test data. Model No.: PS-C2000A
LLWYTH I LAWR I PDF
Manylion
Tagiau
Cyflwyniad Pwynt Gwerthu Cynnyrch
  1. High automation, heating, measuring dielectric loss, and measuring resistivity can be completed at a time.
  2. The three electrode type structure with an GB/T5654-2007 standard, inter electrode spacing 2mm, can eliminate stray capacitance and leakage effect on the dielectric loss test results.
  3. The instrument uses medium frequency induction heating, PID temperature control algorithm. This heating mode has the advantages of non-contact, oil cup and heating body, uniform heating speed, convenient control, the temperature control in temperature within the preset range error.
  4. Using advanced DSP and FFT technology to ensure the stability, accuracy and reliability of the data
  5.  Internal standard capacitor for the SF6 charging three pole capacitor, dielectric loss and capacitance of the capacitor is not affected by ambient temperature, humidity, etc., so that the accuracy of the instrument after a long time to use is still guaranteed.
  6.  Large screen color touch screen, man-machine dialogue convenient, concise operation, clear.
  7.  With the lid off the high voltage, high voltage electrode cup short reminder, eliminate safety hazards, to ensure the normal operation of the safety of operating personnel and equipment.
  8.  With real-time clock, test date, time can be saved with the test results, display, print; equipment can display the ambient temperature, real-time detection of the test environment.
  9.  Automatic storage measurement data, can store 100 sets of measurement data.
  10.  Correction function of empty electrode cup. The capacitance and dielectric loss factor of the empty electrode cup are measured to judge the cleaning and assembling condition of the empty electrode cup. The calibration data are saved automatically to facilitate the accurate calculation of relative capacitance and DC resistivity.
  11. Automatic emptying cup without disassembly, convenient and quick.
Paramedrau Cynnyrch

 

Paramedr

Mynegai

Paramedr

Mynegai

mesur
Amrediad

Cynhwysedd

5pF - 200pF

Datrys pŵer

Cynhwysedd

0.01pF

Colled dielectrig

0.00001 ~ 100

Colled dielectrig

10-5

Gwrthedd

2.5MΩm~20TΩm

Gwrthedd

0.001M

Mesur
cywirdeb

Cynhwysedd

0.5%+1PF

Cywirdeb rheoli

±0.5 ℃

Colled dielectrig

±(1% Darllen+0.0001)

Amrediad tymheredd

0 ~ 125 ℃

Gwrthedd

±10% Darllen

foltedd AC

AC 0 ~ 2200V

Foltedd DC

DC 0 ~ 600V

Tymheredd amgylchynol

0 ~ 40 ℃

Lleithder amgylchynol

<80% RH

Cyflenwad pŵer gweithio

AC220V ±10% (50 ± 1) Hz

Maint

420mm*380mm*420mm

Grym

100W

Pwysau

21Kg (Cwpan am ddim)

 

Fideo

 

capacitor tan delta

dielectric loss tester

insulating oil tester

insulation oil testing

oil tan delta

oil tan delta tester

oil tester

oil tester kit

tan delta meter

tan delta tester

transformer oil tester

transformer oil tester price

volume resistivity tester

Os oes gennych ddiddordeb yn ein cynnyrch, gallwch ddewis gadael eich gwybodaeth yma, a byddwn yn cysylltu â chi yn fuan.


Ysgrifennwch eich neges yma a'i hanfon atom
Cysylltiedig Newyddion
  • Low-Temperature Kinematic Viscosity Testing: A Practical Guide
    Low-Temperature Kinematic Viscosity Testing: A Practical Guide
    Explore low-temperature kinematic viscosity testing, its measurement principles, and key equipment selection considerations. Learn how to distinguish capillary testing from rotational viscosity methods and what information to provide when discussing laboratory requirements with Baoding Push Electrical Manufacturing Co., Ltd.
    Manylyn
  • Comprehensive Guide to Insulating Oil BDV Testers for Transformer Maintenance
    Comprehensive Guide to Insulating Oil BDV Testers for Transformer Maintenance
    Learn what an insulating oil BDV tester measures, how breakdown voltage testing supports transformer maintenance, and which features to consider when choosing equipment for your laboratory or maintenance team.
    Manylyn
  • Find the Right Insulating Oil BDV Tester for Reliable Transformer Maintenance
    Find the Right Insulating Oil BDV Tester for Reliable Transformer Maintenance
    Explore how to choose an insulating oil BDV tester for transformer maintenance and laboratory testing. Compare single-cup and multi-cup configurations, key purchasing factors, and testing requirements with PUSH Tester.
    Manylyn

Os oes gennych ddiddordeb yn ein cynnyrch, gallwch ddewis gadael eich gwybodaeth yma, a byddwn yn cysylltu â chi yn fuan.