PUSH electricalPS-C2000A insulating oil dielectric loss and volume resistivity tester

PS-C2000A Insulating oil dielectric loss tester /Oil tan delta tester is new generation of fully automatic portable insulating oil dielectric loss and resistivity meter designed according to ASTM D924 and GB/5654.7-inch color touch screen It is used for measuring dielectric dissipation factor and DC resistivity of insulating oil and other insulating liquids. It is easy to operate with reliable and accurate test data. Model No.: PS-C2000A
DOWNLOAD RAU PDF
Paub meej
Cim npe
Khoom Muag Khoom Taw Qhia
  1. High automation, heating, measuring dielectric loss, and measuring resistivity can be completed at a time.
  2. The three electrode type structure with an GB/T5654-2007 standard, inter electrode spacing 2mm, can eliminate stray capacitance and leakage effect on the dielectric loss test results.
  3. The instrument uses medium frequency induction heating, PID temperature control algorithm. This heating mode has the advantages of non-contact, oil cup and heating body, uniform heating speed, convenient control, the temperature control in temperature within the preset range error.
  4. Using advanced DSP and FFT technology to ensure the stability, accuracy and reliability of the data
  5.  Internal standard capacitor for the SF6 charging three pole capacitor, dielectric loss and capacitance of the capacitor is not affected by ambient temperature, humidity, etc., so that the accuracy of the instrument after a long time to use is still guaranteed.
  6.  Large screen color touch screen, man-machine dialogue convenient, concise operation, clear.
  7.  With the lid off the high voltage, high voltage electrode cup short reminder, eliminate safety hazards, to ensure the normal operation of the safety of operating personnel and equipment.
  8.  With real-time clock, test date, time can be saved with the test results, display, print; equipment can display the ambient temperature, real-time detection of the test environment.
  9.  Automatic storage measurement data, can store 100 sets of measurement data.
  10.  Correction function of empty electrode cup. The capacitance and dielectric loss factor of the empty electrode cup are measured to judge the cleaning and assembling condition of the empty electrode cup. The calibration data are saved automatically to facilitate the accurate calculation of relative capacitance and DC resistivity.
  11. Automatic emptying cup without disassembly, convenient and quick.
Khoom Parameters

 

Parameter

Index

Parameter

Index

ntsuas
Ntau yam

Capacitance

5 pF ~ 200 pF

Kev daws lub zog

Capacitance

0,01f wb

Dielectric poob

0.00001 ~ 100

Dielectric poob

10-5

Kev tiv thaiv

2.5MΩm ~ 20TΩm

Kev tiv thaiv

0,001 M

Ntsuas
raug

Capacitance

0.5% + 1 PF

Tswj qhov tseeb

± 0.5 ℃

Dielectric poob

± (1% Nyeem ntawv + 0.0001)

Qhov kub thiab txias

0 ~ 125 ℃

Kev tiv thaiv

± 10% Kev nyeem ntawv

AC voltage

AC 0 ~ 2200V

DC voltage

DC 0 ~ 600V

Ambient kub

0 ~ 40 ℃

Ambient humidity

80% RH

Ua haujlwm fais fab

AC220V ± 10% (50 ± 1) Hz

Loj

420mm * 380mm * 420mm

Hwj chim

100 W

Qhov hnyav

21Kg (dawb khob)

 

Video

 

capacitor tan delta

dielectric loss tester

insulating oil tester

insulation oil testing

oil tan delta

oil tan delta tester

oil tester

oil tester kit

tan delta meter

tan delta tester

transformer oil tester

transformer oil tester price

volume resistivity tester

Yog tias koj txaus siab rau peb cov khoom, koj tuaj yeem xaiv tawm koj cov ntaub ntawv ntawm no, thiab peb yuav tiv tauj koj sai sai.


Sau koj cov lus ntawm no thiab xa tuaj rau peb
Hais txog Xov xwm
  • Find the Best Loop Impedance Tester for Sale and Ensure Electrical Safety
    Find the Best Loop Impedance Tester for Sale and Ensure Electrical Safety
    When ensuring electrical safety, accurate loop impedance testing is crucial. Whether you’re an electrician, a facilities manager, or a safety inspector, having a reliable loop impedance tester for sale is essential. This article will guide you through the key considerations when purchasing a loop impedance tester, explore the different types available, and highlight the benefits of choosing a high-quality instrument. Understanding the nuances of these testers will help you make an informed decision and ensure compliance with safety regulations.
    Paub meej
  • Comprehensive Guide to Loop Impedance Meter for Electrical Safety
    Comprehensive Guide to Loop Impedance Meter for Electrical Safety
    Ensuring electrical safety is paramount in any installation, and a loop impedance meter is a crucial tool for achieving this. This device measures the total impedance of the earth fault loop, helping to verify that protective devices will operate correctly under fault conditions. In this article, we'll explore what a loop impedance meter is, how it works, its applications, factors influencing measurements, choosing the right meter, and the importance of regular testing. Investing in a quality meter from Push Tester is a step towards safer electrical systems.
    Paub meej
  • Understanding and Choosing a Line Impedance Tester for Optimal Network Performance
    Understanding and Choosing a Line Impedance Tester for Optimal Network Performance
    In the realm of telecommunications and electrical engineering, maintaining the integrity of transmission lines is paramount. A line impedance tester is a crucial instrument for ensuring optimal signal transmission and preventing costly network disruptions. This article delves into the world of line impedance testing, exploring its importance, applications, types of testers, and what to look for when making a purchase. Ensuring accurate impedance measurements is essential for efficient and reliable network performance. Choosing the right tester can significantly impact troubleshooting speed and the overall quality of your infrastructure. A line impedance tester, also known as a cable impedance analyzer, is a device used to measure the characteristic impedance of coaxial cables, twisted pair cables, and other transmission lines. Impedance, measured in ohms, represents the opposition to the flow of alternating current. Maintaining the correct impedance (typically 50 or 75 ohms) is vital for minimizing signal reflections, ensuring efficient power transfer, and preventing signal degradation. Mismatched impedance can lead to signal loss, ghosting, and reduced network performance. Regular testing helps identify faults and maintain network integrity.
    Paub meej

Yog tias koj txaus siab rau peb cov khoom, koj tuaj yeem xaiv tawm koj cov ntaub ntawv ntawm no, thiab peb yuav tiv tauj koj sai sai.