EnglishLus Askiv

PUSH Eletrical PS-C2001A Fully automatic oil drain dielectric loss and volume resistivity tester oil tan delta tester

PS-C2001A Insulating oil dielectric loss tester /Oil tan delta tester is new generation of fully automatic portable insulating oil dielectric loss and resistivity meter designed according to ASTM D924 and GB/5654. 7-inch color touch screen It is used for measuring dielectric dissipation factor and DC resistivity of insulating oil and other insulating liquids. It is easy to operate with reliable and accurate test data. Model No.: PS-C2001A
DOWNLOAD RAU PDF
Paub meej
Cim npe
Khoom Muag Khoom Taw Qhia
  1. High automation, heating, measuring dielectric loss, and measuring resistivity can be completed at a time.
  2. The three electrode type structure with an GB/T5654-2007 standard, inter electrode spacing 2mm, can eliminate stray capacitance and leakage effect on the dielectric loss test results.
  3. The instrument uses medium frequency induction heating, PID temperature control algorithm. This heating mode has the advantages of non-contact, oil cup and heating body, uniform heating speed, convenient control, the temperature control in temperature within the preset range error.
  4. Using advanced DSP and FFT technology to ensure the stability, accuracy and reliability of the data
  5.  Internal standard capacitor for the SF6 charging three pole capacitor, dielectric loss and capacitance of the capacitor is not affected by ambient temperature, humidity, etc., so that the accuracy of the instrument after a long time to use is still guaranteed.
  6.  Large screen color touch screen, man-machine dialogue convenient, concise operation, clear.
  7.  With the lid off the high voltage, high voltage electrode cup short reminder, eliminate safety hazards, to ensure the normal operation of the safety of operating personnel and equipment.
  8.  With real-time clock, test date, time can be saved with the test results, display, print; equipment can display the ambient temperature, real-time detection of the test environment.
  9.  Automatic storage measurement data, can store 100 sets of measurement data.
  10.  Correction function of empty electrode cup. The capacitance and dielectric loss factor of the empty electrode cup are measured to judge the cleaning and assembling condition of the empty electrode cup. The calibration data are saved automatically to facilitate the accurate calculation of relative capacitance and DC resistivity.
  11. Automatic emptying cup without disassembly, convenient and quick.
Khoom Parameters

 

Parameter

Index

Parameter

Index

ntsuas
Ntau yam

Capacitance

5 pF ~ 200 pF

Kev daws lub zog

Capacitance

0,01f wb

Dielectric poob

0.00001 ~ 100

Dielectric poob

10-5

Kev tiv thaiv

2.5MΩm ~ 20TΩm

Kev tiv thaiv

0,001 M

Ntsuas
raug

Capacitance

0.5% + 1 PF

Tswj qhov tseeb

± 0.5 ℃

Dielectric poob

± (1% Nyeem ntawv + 0.0001)

Qhov kub thiab txias

0 ~ 125 ℃

Kev tiv thaiv

± 10% Kev nyeem ntawv

AC voltage

AC 0 ~ 2200V

DC voltage

DC 0 ~ 600V

Ambient kub

0 ~ 40 ℃

Ambient humidity

80% RH

Ua haujlwm fais fab

AC220V ± 10% (50 ± 1) Hz

Loj

420mm * 380mm * 420mm

Hwj chim

100 W

Qhov hnyav

21Kg (dawb khob)

 

Video

 

dielectric loss factor

dielectric loss meter

dielectric loss tangent

dielectric loss test

dielectric loss tester

oil tan delta

oil tan delta tester

tan delta meter

tan delta system

tan delta test

tan delta tester

test tan delta

transformer tan delta

volume resistivity tester

Yog tias koj txaus siab rau peb cov khoom, koj tuaj yeem xaiv tawm koj cov ntaub ntawv ntawm no, thiab peb yuav tiv tauj koj sai sai.


Sau koj cov lus ntawm no thiab xa tuaj rau peb
Hais txog Xov xwm
  • Low-Temperature Kinematic Viscosity Testing: A Practical Guide
    Low-Temperature Kinematic Viscosity Testing: A Practical Guide
    Explore low-temperature kinematic viscosity testing, its measurement principles, and key equipment selection considerations. Learn how to distinguish capillary testing from rotational viscosity methods and what information to provide when discussing laboratory requirements with Baoding Push Electrical Manufacturing Co., Ltd.
    Paub meej
  • Comprehensive Guide to Insulating Oil BDV Testers for Transformer Maintenance
    Comprehensive Guide to Insulating Oil BDV Testers for Transformer Maintenance
    Learn what an insulating oil BDV tester measures, how breakdown voltage testing supports transformer maintenance, and which features to consider when choosing equipment for your laboratory or maintenance team.
    Paub meej
  • Find the Right Insulating Oil BDV Tester for Reliable Transformer Maintenance
    Find the Right Insulating Oil BDV Tester for Reliable Transformer Maintenance
    Explore how to choose an insulating oil BDV tester for transformer maintenance and laboratory testing. Compare single-cup and multi-cup configurations, key purchasing factors, and testing requirements with PUSH Tester.
    Paub meej

Yog tias koj txaus siab rau peb cov khoom, koj tuaj yeem xaiv tawm koj cov ntaub ntawv ntawm no, thiab peb yuav tiv tauj koj sai sai.