PS-ZRD03 astm d217 Lubricating Grease Cone Lubricity Oil Penetration Tester Penetrometer

Enstriman sa a fèt ak fabrike dapre dispozisyon ki enpòtan nan estanda nasyonal GB/T269 "Detèminasyon Penetrasyon nan grès lubrifyan ak grès petwòl", ki se apwopriye pou mezire pénétration nan divès kalite grès lubrifyan ak grès petwòl. Li kapab tou ekipe ak zegwi estanda ki enpòtan pou tès materyèl nan patikil solid solid, poud, oswa koloyid, kò nan frizè, elatriye ak enspeksyon an nan fwomaj, chiklèt sik, bè, bè, kò fèrmante ak lòt matyè premyè manje. Enstriman sa a apwopriye tou pou ISO2137-85 "Detèminasyon Penetrasyon grès ak grès petwòl"; ASTMD217-82, IP50-79 "Detèminasyon Penetrasyon nan grès"
DESANN CHAJE POU PDF
Detay yo
Tags
Pwodwi Vann Pwen Entwodiksyon

 

  1. Kòn Penetration Tester pou grès lubrifyan, konnen tou kòm yon Penetrometer kòn grès, se yon enstriman espesyalize ki itilize pou mezire konsistans oswa pwofondè pénétration grès lubrifyan nan kondisyon estanda. Li evalye degre nan dite oswa tendres nan grès, ki se kritik pou detèmine konvnab li pou aplikasyon pou divès kalite ak asire pèfòmans optimal nan machin ak ekipman.

 

Aplikasyon

 

- Kontwòl Kalite: Yo itilize pa manifaktirè lubrifyan ak laboratwa kontwòl kalite pou evalye konsistans ak pèfòmans grès lubrifyan, asire konfòmite ak estanda endistri yo ak espesifikasyon yo.

- Devlopman pwodwi: Èd nan fòmilasyon ak devlopman nan grès lubrifyan ak konsistans vle, viskozite, ak karakteristik pénétration pou aplikasyon espesifik ak kondisyon opere.

  • - Antretyen machin: Teknisyen antretyen ak enjenyè anplwaye yo pou kontwole kondisyon grès lubrifyan nan machin ak ekipman, detekte chanjman nan konsistans ki ka endike degradasyon oswa kontaminasyon.

 

Sèvi ak ka yo

 

- Seleksyon grès: Ede itilizatè yo chwazi klas ki apwopriye oswa kalite grès lubrifyan ki baze sou karakteristik pénétration li yo ak kondisyon fonksyònman, tankou tanperati, chaj, ak vitès.

- Lubrifyan Ekipman: Li gide bon lubrification nan konpozan machin, tankou BEARINGS, angrenaj, ak sele, lè w asire konsistans kòrèk la nan grès aplike pou pèfòmans optimal ak rezistans.

  • - Evalyasyon Pèfòmans: Ede nan evalye efikasite grès lubrifyan nan diminye friksyon, mete, ak korozyon nan sistèm mekanik, kidonk pwolonje lavi sèvis ekipman yo ak minimize D '.

 

Fonksyonalite

 

Kòn Penetration Tester pou grès lubrifyan konsiste de yon pwofonde pénétromètr ki gen fòm yon kòn ki tache ak yon baton kalibre oswa arbr. Pwofonde a vètikal kondwi nan yon echantiyon grès lubrifyan nan yon pousantaj kontwole, epi pwofondè nan pénétration mezire ak anrejistre. Pwofondè pénétration endike konsistans oswa determinasyon grès la, ak grès douser ki montre pi gwo pwofondè pénétration ak grès pi difisil ki montre pi ba pwofondè pénétration. Rezilta tès yo bay bonjan enfòmasyon sou pwopriyete reolojik grès lubrifyan yo, ki gen ladan rezistans yo nan deformation, estabilite taye taye, ak entegrite estriktirèl. Sa a ede manifakti lubrifyan, itilizatè yo, ak pwofesyonèl antretyen asire pèfòmans nan pi bon ak fyab nan machin ak ekipman wile.

 

Paramèt pwodwi

 

ekspozisyon pénétration

LCD ekspozisyon dijital, presizyon 0.01mm

(0.1 pénétration kòn)

pwofondè maksimòm son

pi gran pase 620 kòn pénétration

revèy mete pens

0 ~ 99 segonn ± 0.1 segonn

ekipman pou pouvwa enstriman

220V±22V,50Hz±1Hz

batri ekspozisyon kòn pénétration

LR44H bouton batri

grease penetrometer

grease tester

oil penetration tester

Si ou enterese nan pwodwi nou yo, ou ka chwazi kite enfòmasyon ou isit la, epi nou pral kontakte ou yon ti tan.


Ekri mesaj ou la a epi voye l ba nou
Ki gen rapò Nouvèl
  • Find the Best Loop Impedance Tester for Sale and Ensure Electrical Safety
    Find the Best Loop Impedance Tester for Sale and Ensure Electrical Safety
    When ensuring electrical safety, accurate loop impedance testing is crucial. Whether you’re an electrician, a facilities manager, or a safety inspector, having a reliable loop impedance tester for sale is essential. This article will guide you through the key considerations when purchasing a loop impedance tester, explore the different types available, and highlight the benefits of choosing a high-quality instrument. Understanding the nuances of these testers will help you make an informed decision and ensure compliance with safety regulations.
    Detay
  • Comprehensive Guide to Loop Impedance Meter for Electrical Safety
    Comprehensive Guide to Loop Impedance Meter for Electrical Safety
    Ensuring electrical safety is paramount in any installation, and a loop impedance meter is a crucial tool for achieving this. This device measures the total impedance of the earth fault loop, helping to verify that protective devices will operate correctly under fault conditions. In this article, we'll explore what a loop impedance meter is, how it works, its applications, factors influencing measurements, choosing the right meter, and the importance of regular testing. Investing in a quality meter from Push Tester is a step towards safer electrical systems.
    Detay
  • Understanding and Choosing a Line Impedance Tester for Optimal Network Performance
    Understanding and Choosing a Line Impedance Tester for Optimal Network Performance
    In the realm of telecommunications and electrical engineering, maintaining the integrity of transmission lines is paramount. A line impedance tester is a crucial instrument for ensuring optimal signal transmission and preventing costly network disruptions. This article delves into the world of line impedance testing, exploring its importance, applications, types of testers, and what to look for when making a purchase. Ensuring accurate impedance measurements is essential for efficient and reliable network performance. Choosing the right tester can significantly impact troubleshooting speed and the overall quality of your infrastructure. A line impedance tester, also known as a cable impedance analyzer, is a device used to measure the characteristic impedance of coaxial cables, twisted pair cables, and other transmission lines. Impedance, measured in ohms, represents the opposition to the flow of alternating current. Maintaining the correct impedance (typically 50 or 75 ohms) is vital for minimizing signal reflections, ensuring efficient power transfer, and preventing signal degradation. Mismatched impedance can lead to signal loss, ghosting, and reduced network performance. Regular testing helps identify faults and maintain network integrity.
    Detay

Si ou enterese nan pwodwi nou yo, ou ka chwazi kite enfòmasyon ou isit la, epi nou pral kontakte ou yon ti tan.