EnglishIcyongereza

PUSH Electrical PS-DC10A Transformer DC Winding Resistance Tester

Impinduka DC irwanya ibizamini. Igikoresho gikoresha uburyo bushya bwo gutanga amashanyarazi, bufite ibiranga ubunini buto, uburemere bworoshye, ibisohoka binini bigezweho, gusubiramo neza, imbaraga zikomeye zo kurwanya-kwivanga, nibikorwa byiza byo kurinda. Imashini yose igenzurwa na yihuta yihuta ya chip-microcomputer, hamwe nurwego rwo hejuru rwikora, hamwe no gusohora byikora no gusohora ibikorwa byo gutabaza. Igikoresho gifite ibipimo bihanitse kandi bikora byoroshye, bishobora kumenya igipimo cyihuse cyo guhinduranya ibintu.
SHAKA UMURONGO Kuri PDF
Ibisobanuro
Etiquetas
Ibicuruzwa byo kugurisha

 

  1. 1. Igikoresho kirashobora gukoresha terefone cyangwa tableti ya Android, gukurikira konte yemewe ya WeChat, gukuramo APP idasanzwe, kugenzura igikoresho ukoresheje porogaramu idasanzwe, no kubika no kohereza amakuru yikizamini kugirango byoroshye gukoreshwa.
    2. Umuvuduko mwinshi wibikoresho byigikoresho ni 24V, byoroshye guhitamo ikizamini kinini mugihe ikigereranyo kiri hejuru, no kuzamura umuvuduko wikizamini
    3. Igikoresho gikoresha uburyo bushya bwo gutanga amashanyarazi, hamwe nibikoresho byinshi bigezweho hamwe nubunini bwagutse. Ibiriho birashobora guhita bitoranywa ukurikije umutwaro, bikwiranye no gupima DC kurwanya ibipimo bito bito n'ibiciriritse na transformateur ya voltage.
    4. Ifite ibikorwa byinshi byo kurinda nkibisubizo byinyuma-EMF, guhagarika no kunanirwa kwamashanyarazi mugihe cyikizamini, hamwe nubushyuhe bukabije bwamashanyarazi, bishobora kurinda byimazeyo igikoresho cyinyuma-EMF hamwe nijwi ryumvikana.
    5. Hamwe nubushuhe ubwo aribwo bwose bwo guhindura ibikoresho byumuringa na aluminiyumu, kora ibyinjijwe mubushyuhe ubwo aribwo bwose hamwe nubushyuhe bwahinduwe.
    6. Ubuhanga bwubwenge bwo gucunga ingufu, igikoresho gihora gikora mumbaraga nkeya, zibika neza ingufu kandi kigabanya ubushyuhe.
    7. Ibara rya santimetero ndwi-cyane-gukoraho ibara rya LCD, kwerekana neza munsi yumucyo ukomeye, gukora ecran yuzuye, gukora kubuntu hagati yubushinwa nicyongereza.
    8. Igikoresho kizana isaha ya kalendari yigihe cyose hamwe nububiko bwamanutse, bushobora kubika ibice 1000 byamakuru yikizamini, gishobora kugirwa inama igihe icyo aricyo cyose.
    9. Igikoresho gifite itumanaho rya Bluetooth, itumanaho RS232 hamwe na USB interineti yo gutumanaho mudasobwa hamwe no kubika amakuru ya U disiki.
    10. Iza ifite icapiro ryubwoko bwa micro printer, ishobora gusohora ibisubizo byo gupima mubushinwa.

 

Ibicuruzwa 

 

umushinga

Ibipimo bya tekiniki n'ibipimo

Ikizamini kigezweho

AUTO 、 <20mA 、 40mA 、 200mA 、 1A 、 5A 、 10A

Gupima intera nukuri

0.5mΩ ~ 0.8Ω (10A)
1mΩ-4Ω (5A)
5mΩ-20Ω (1 A)
100mΩ-100Ω (200mA)
1Ω-500Ω (40mA)

± (0.2% + amagambo 2)

 

100Ω-100KΩ (<20mA)

± (0.5% + amagambo 2)

Icyemezo ntarengwa

0.1μΩ

kwerekana

Ibara rya santimetero ndwi LCD

Kurwanya kwerekana imibare ifatika ni imibare 4

Kubika amakuru

Amatsinda 1000

ibidukikije

Ubushyuhe bwibidukikije: 0 ℃ ~ 40 idity Ubushuhe bugereranije: <90% RH, nta kondegene

amashanyarazi

AC 220V ± 10V , 50Hz ± 1 Hz

Umuyoboro w'ubwishingizi 2A

Gukoresha ingufu nyinshi

200W

Ibipimo

360 * 290 * 170 (mm)

uburemere

Nyiricyubahiro: 6 KG Agasanduku: 5 KG

 

Kugurisha Ingingo Intangiriro

 

dc hi pot test

dc hipot

dc hipot test voltage

dc insulation resistance test

dc resistance tester

dc winding resistance

dc winding resistance test

dc winding resistance test of transformer

dc winding resistance tester

transformer dc winding resistance tester

Niba ushimishijwe nibicuruzwa byacu, urashobora guhitamo gusiga amakuru yawe hano, kandi tuzahuza nawe vuba.


Andika ubutumwa bwawe hano hanyuma utwohereze
Bifitanye isano Amakuru
  • Find the Best Loop Impedance Tester for Sale and Ensure Electrical Safety
    Find the Best Loop Impedance Tester for Sale and Ensure Electrical Safety
    When ensuring electrical safety, accurate loop impedance testing is crucial. Whether you’re an electrician, a facilities manager, or a safety inspector, having a reliable loop impedance tester for sale is essential. This article will guide you through the key considerations when purchasing a loop impedance tester, explore the different types available, and highlight the benefits of choosing a high-quality instrument. Understanding the nuances of these testers will help you make an informed decision and ensure compliance with safety regulations.
    Ibisobanuro
  • Comprehensive Guide to Loop Impedance Meter for Electrical Safety
    Comprehensive Guide to Loop Impedance Meter for Electrical Safety
    Ensuring electrical safety is paramount in any installation, and a loop impedance meter is a crucial tool for achieving this. This device measures the total impedance of the earth fault loop, helping to verify that protective devices will operate correctly under fault conditions. In this article, we'll explore what a loop impedance meter is, how it works, its applications, factors influencing measurements, choosing the right meter, and the importance of regular testing. Investing in a quality meter from Push Tester is a step towards safer electrical systems.
    Ibisobanuro
  • Understanding and Choosing a Line Impedance Tester for Optimal Network Performance
    Understanding and Choosing a Line Impedance Tester for Optimal Network Performance
    In the realm of telecommunications and electrical engineering, maintaining the integrity of transmission lines is paramount. A line impedance tester is a crucial instrument for ensuring optimal signal transmission and preventing costly network disruptions. This article delves into the world of line impedance testing, exploring its importance, applications, types of testers, and what to look for when making a purchase. Ensuring accurate impedance measurements is essential for efficient and reliable network performance. Choosing the right tester can significantly impact troubleshooting speed and the overall quality of your infrastructure. A line impedance tester, also known as a cable impedance analyzer, is a device used to measure the characteristic impedance of coaxial cables, twisted pair cables, and other transmission lines. Impedance, measured in ohms, represents the opposition to the flow of alternating current. Maintaining the correct impedance (typically 50 or 75 ohms) is vital for minimizing signal reflections, ensuring efficient power transfer, and preventing signal degradation. Mismatched impedance can lead to signal loss, ghosting, and reduced network performance. Regular testing helps identify faults and maintain network integrity.
    Ibisobanuro

Niba ushimishijwe nibicuruzwa byacu, urashobora guhitamo gusiga amakuru yawe hano, kandi tuzahuza nawe vuba.