PUSH Electrical PS-Vlfz 80kv 60kv 30kv Color Touch Screen High Voltage Ac Hv Vlf Hipot Tester

I-ultra low frequency ne-high voltage generator ingumkhiqizo oyinhloko othuthukiswe ngokuzimela kusetshenziswa ubuchwepheshe bamuva e-United States. Isebenzisa isikrini sokuthinta esingu-7 intshi, i-ARM7 single chip microcomputer yakamuva, isekethe yokutholwa kwe-AD enesivinini esiphezulu kanye nesofthiwe yokuphatha ingemuva. Inezici zomsindo ophansi, ukonga amandla, i-sine wave high-voltage waveform, high-voltage electronic switch polarity nokunye.
LAYISHA KU-PDF
Imininingwane
Omaka
Isingeniso Sendawo Yokuthengisa Umkhiqizo

 

  1. 1. Ubuchwepheshe obuthuthukisiwe: ubuchwepheshe bokuguqula imvamisa yedijithali, ukulawula ikhompuyutha encane, ukukhuphuka kwengcindezi, ukunciphisa ingcindezi, ukulinganisa, ukuvikela, njll.
    2. Inqubo yokuhlola i-othomathikhi ngokugcwele.
    3. Kulula ukusebenza: i-wiring elula, ukusebenza kwesiwula.
    4. Ukuvikela okuphelele: ukuvikela okuningi (ukuvikela amandla kagesi angaphezu kwamandla kagesi, ukuvikela okungaphezulu kwamanje emaceleni kagesi aphezulu naphansi), isenzo esisheshayo (uma sisebenza)
    5. Igumbi ≤10ms), ithuluzi liphephile futhi linokwethenjelwa.
    6. Ukuphepha nokuthembeka: isilawuli sixhunywe ne-voltage ephansi yejeneretha yamandla kagesi aphezulu, ngokulawulwa kwezithombe zikagesi, ukusetshenziswa okuphephile nokuthembekile.
    7. Isekhethi yokulawula impendulo ye-voltage ephezulu nephansi ivaliwe, futhi okukhiphayo akunawo umphumela wokukhuphuka komthamo.
    8. Ukucushwa okuphelele: isikrini sokuthinta i-capacitive, isibonisi sezinhlamvu zesiShayina se-LCD, isitoreji esizenzakalelayo, ukuphrinta okuzenzakalelayo.
    9. Ibanga elikhulu lokuhlola: 0.1Hz, 0.05Hz kanye no-0.02hz ukukhethwa kwamafrikhwensi amaningi, ububanzi bokuhlola obukhulu.
    10. Ivolumu encane nesisindo esincane: kulula kakhulu ekusebenzeni kwangaphandle.

 

Ipharamitha Yomkhiqizo

 

Imodi

I-Voltage elinganiselwe

Layisha

Fuse

Isisindo

40KV /1.1

40kv (inani eliphakeme)

0.1Hz,≤1.1µF

8A

Isilawuli: 6Kg
I-Booster: 20Kg

0.05Hz,≤2.2µF

0.02Hz,≤5.5µF

50KV /1.1

50kv (inani eliphakeme)

0.1Hz,≤1.1µF

10A

Isilawuli: 6Kg
I-Booster: 45Kg

0.05Hz,≤2.2µF

0.02Hz,≤5.5µF

80KV /1.1

80kv (inani eliphakeme)

0.1Hz,≤1.1µF

20A

Isilawuli: 4Kg
amandla: 50Kg

0.05Hz,≤2.2µF

 

 

0.02Hz,≤5.5µF

 

 

 

Ividiyo

 

ac hipot

dc hipot

hi pot testers

high voltage withstand test

hipot analyzer

hipot cables

hipot equipment

hipot kit

hipot meter

hipot vlf

hipot voltage

vlf hipot

vlf tan delta cable testing

vlf tester

Uma unentshisekelo ngemikhiqizo yethu, ungakhetha ukushiya imininingwane yakho lapha, futhi sizokuthinta maduzane.


Bhala umyalezo wakho lapha futhi usithumelele wona
Okuhlobene Izindaba
  • Find the Best Loop Impedance Tester for Sale and Ensure Electrical Safety
    Find the Best Loop Impedance Tester for Sale and Ensure Electrical Safety
    When ensuring electrical safety, accurate loop impedance testing is crucial. Whether you’re an electrician, a facilities manager, or a safety inspector, having a reliable loop impedance tester for sale is essential. This article will guide you through the key considerations when purchasing a loop impedance tester, explore the different types available, and highlight the benefits of choosing a high-quality instrument. Understanding the nuances of these testers will help you make an informed decision and ensure compliance with safety regulations.
    Imininingwane
  • Comprehensive Guide to Loop Impedance Meter for Electrical Safety
    Comprehensive Guide to Loop Impedance Meter for Electrical Safety
    Ensuring electrical safety is paramount in any installation, and a loop impedance meter is a crucial tool for achieving this. This device measures the total impedance of the earth fault loop, helping to verify that protective devices will operate correctly under fault conditions. In this article, we'll explore what a loop impedance meter is, how it works, its applications, factors influencing measurements, choosing the right meter, and the importance of regular testing. Investing in a quality meter from Push Tester is a step towards safer electrical systems.
    Imininingwane
  • Understanding and Choosing a Line Impedance Tester for Optimal Network Performance
    Understanding and Choosing a Line Impedance Tester for Optimal Network Performance
    In the realm of telecommunications and electrical engineering, maintaining the integrity of transmission lines is paramount. A line impedance tester is a crucial instrument for ensuring optimal signal transmission and preventing costly network disruptions. This article delves into the world of line impedance testing, exploring its importance, applications, types of testers, and what to look for when making a purchase. Ensuring accurate impedance measurements is essential for efficient and reliable network performance. Choosing the right tester can significantly impact troubleshooting speed and the overall quality of your infrastructure. A line impedance tester, also known as a cable impedance analyzer, is a device used to measure the characteristic impedance of coaxial cables, twisted pair cables, and other transmission lines. Impedance, measured in ohms, represents the opposition to the flow of alternating current. Maintaining the correct impedance (typically 50 or 75 ohms) is vital for minimizing signal reflections, ensuring efficient power transfer, and preventing signal degradation. Mismatched impedance can lead to signal loss, ghosting, and reduced network performance. Regular testing helps identify faults and maintain network integrity.
    Imininingwane

Uma unentshisekelo ngemikhiqizo yethu, ungakhetha ukushiya imininingwane yakho lapha, futhi sizokuthinta maduzane.