Main Technical Characteristics


★ It has comprehensive functions, which not only meets the test requirements of excitation characteristics (V-I characteristics), ratio, polarity, secondary winding resistance, secondary load, ratio error and angle error of various CT (such as: protection, measurement and TP class), but also can be used for the test of excitation characteristics, ratio, polarity, secondary winding resistance of various PT electromagnetic units.
★ The parameters of inflection point voltage / current, 10% (5%) error curve, accurate limit coefficient (ALF), instrument security coefficient (FS), secondary time constant (Ts), residual magnetic coefficient (Kr), and saturation inductance are automatically given.
★ The test meets the standards of transformers such as GB1208 (IEC60044-1), GB16847 (IEC60044-6), GB1207, etc., and is automatically selected according to the transformer type and level.
★ Based on the advanced low-frequency method test principle, it can deal with CT tests with inflection points of up to 80KV.
★ The instrument adopts the international popular square wave method to make the excitation curve more perfect.
★ The instrument can store 3000 sets of test data, power loss without loss.
★ The test is simple and convenient, to complete the CT direct resistance, excitation, ratio and polarity test with one key, and in addition to the load test, CT adopts the same wiring test.
★ Easy to carry, the instrument weighs about 7Kg.

Main Technical Parameters

 

Input power voltage

AC 100~264V,50/60Hz

Lähtö

0~180V rms, 12A rms, 36A (peak)

Voltage measurement accuracy

Range: 2~200Vrms, precision: ± 0.1%

CT variation ratio measurements

Range: 1~40000, precision: ± 0.05%

PT variation ratio measurements

Range: 1~40000, precision: ± 0.1%

Vaiheen mittaus

Precision: ± 2min, resolution: 0.5min

Turbine resistance measurement

Range: 0~300 Ω, precision: 0.2% ± 2m

AC-kuormituksen mittaus

Range: 0~1000VA, precision: 0.2%±0.02VA

Työympäristö

temperature:-20οC~50οC, humidity: 90%

Size,  weight

Dimensions: 340 mm 260 mm 140mm, weight <7.5kg

Jos olet kiinnostunut tuotteistamme, voit jättää tietosi tähän, niin olemme sinuun pian yhteydessä.


Kirjoita viestisi tähän ja lähetä se meille
Liittyvät Uutiset
  • Testing Equipment Industry Sees Major Advancements in 2025: Smart & Precision Technologies Lead the Way
    Testing Equipment Industry Sees Major Advancements in 2025: Smart & Precision Technologies Lead the Way
    Release Date: June 6, 2025 As intelligent manufacturing and quality-driven strategies continue to reshape global industries, the testing equipment sector is experiencing a rapid evolution in 2025. Recent updates in national policy, technology innovation, and industrial demand are driving the industry to new heights.
    Yksityiskohta
  • Applications of Direct Current Generators in Renewable Energy Systems
    Applications of Direct Current Generators in Renewable Energy Systems
    The global shift toward sustainable energy has amplified the demand for efficient power generation and monitoring tools.
    Yksityiskohta
  • Hipot Tester Calibration and Accuracy Guidelines
    Hipot Tester Calibration and Accuracy Guidelines
    For businesses involved in large-scale electrical infrastructure, maintaining the reliability of testing equipment is non-negotiable.
    Yksityiskohta

Jos olet kiinnostunut tuotteistamme, voit jättää tietosi tähän, niin olemme sinuun pian yhteydessä.