Enska


Afrikaans
Albanian
Amharic
Arabic
Armenian
Azerbaijani
Basque
Belarusian
Bengali
Bosnian
Bulgarian
Catalan
Cebuano
China
China (Taiwan)
Corsican
Croatian
Czech
Danish
Dutch
English
Esperanto
Estonian
Finnish
French
Frisian
Galician
Georgian
German
Greek
Gujarati
Haitian Creole
hausa
hawaiian
Hebrew
Hindi
Miao
Hungarian
Icelandic
igbo
Indonesian
irish
Italian
Japanese
Javanese
Kannada
kazakh
Khmer
Rwandese
Korean
Kurdish
Kyrgyz
Lao
Latin
Latvian
Lithuanian
Luxembourgish
Macedonian
Malgashi
Malay
Malayalam
Maltese
Maori
Marathi
Mongolian
Myanmar
Nepali
Norwegian
Norwegian
Occitan
Pashto
Persian
Polish
Portuguese
Punjabi
Romanian
Russian
Samoan
Scottish Gaelic
Serbian
Sesotho
Shona
Sindhi
Sinhala
Slovak
Slovenian
Somali
Spanish
Sundanese
Swahili
Swedish
Tagalog
Tajik
Tamil
Tatar
Telugu
Thai
Turkish
Turkmen
Ukrainian
Urdu
Uighur
Uzbek
Vietnamese
Welsh
Bantu
Yiddish
Yoruba
Zulu
★ It has comprehensive functions, which not only meets the test requirements of excitation characteristics (V-I characteristics), ratio, polarity, secondary winding resistance, secondary load, ratio error and angle error of various CT (such as: protection, measurement and TP class), but also can be used for the test of excitation characteristics, ratio, polarity, secondary winding resistance of various PT electromagnetic units.
★ The parameters of inflection point voltage / current, 10% (5%) error curve, accurate limit coefficient (ALF), instrument security coefficient (FS), secondary time constant (Ts), residual magnetic coefficient (Kr), and saturation inductance are automatically given.
★ The test meets the standards of transformers such as GB1208 (IEC60044-1), GB16847 (IEC60044-6), GB1207, etc., and is automatically selected according to the transformer type and level.
★ Based on the advanced low-frequency method test principle, it can deal with CT tests with inflection points of up to 80KV.
★ The instrument adopts the international popular square wave method to make the excitation curve more perfect.
★ The instrument can store 3000 sets of test data, power loss without loss.
★ The test is simple and convenient, to complete the CT direct resistance, excitation, ratio and polarity test with one key, and in addition to the load test, CT adopts the same wiring test.
★ Easy to carry, the instrument weighs about 7Kg.
|
Input power voltage |
AC 100~264V,50/60Hz |
|
Framleiðsla |
0~180V rms, 12A rms, 36A (peak) |
|
Voltage measurement accuracy |
Range: 2~200Vrms, precision: ± 0.1% |
|
CT variation ratio measurements |
Range: 1~40000, precision: ± 0.05% |
|
PT variation ratio measurements |
Range: 1~40000, precision: ± 0.1% |
|
Fasamæling |
Precision: ± 2min, resolution: 0.5min |
|
Turbine resistance measurement |
Range: 0~300 Ω, precision: 0.2% ± 2m |
|
AC álagsmæling |
Range: 0~1000VA, precision: 0.2%±0.02VA |
|
Vinnu umhverfi |
temperature:-20οC~50οC, humidity: 90% |
|
Size, weight |
Dimensions: 340 mm 260 mm 140mm, weight <7.5kg |
ct and pt testing
ct pt analyzer
ct pt test
ct pt tester
ct pt testing equipment
pt transformer testing