PUSH Electrical PS-RG03 Capacitance Inductance Tester

Hoʻolālā ʻia kēia mea hana no nā pilikia e loaʻa ana i ke ana ʻana o nā panakō kiʻekiʻe shunt capacitor ma nā substations, a pili i GB3983.2-1989 "High-voltage shunt capacitors", DL/T840-2003 "Nā kūlana ʻenehana no ka hoʻohana ʻana i nā kiʻekiʻe kiʻekiʻe. -Voltage shunt capacitors" a me JB5346-1998 " Hoʻomohala kūikawā ʻia e like me nā kūlana ʻāina e like me "Series Reactors", ka mea nui no ke ana ʻana i nā panakō capacitor parallel kiʻekiʻe a me nā reactors o nā mea hoʻihoʻi mana reactive.
IHO IHO I KA PDF
Nā kikoʻī
Nā huaʻōlelo
Huahana Kūʻai Point Introduction

 

  1. 1. Hiki i kēia mea hana ke ana i ka capacitance hoʻokahi o kahi hui o nā capacitors like ʻole me ka wehe ʻole ʻana i nā uea (hiki ke ana ʻia ka capacitance hoʻokahi a me ka capacitance ʻekolu). ʻano hoʻohana.
    2. I ka wā o ke ana ʻana, hiki i ka mea kani ke hōʻike i ka waiwai capacitance i ana ʻia a i ʻole ka waiwai inductance, a hiki ke hōʻike pū i ka volta i ana ʻia, ka manawa, ka mana, ka pinepine, ka impedance, ka angle phase a me nā ʻikepili ʻē aʻe;
    3. Hoʻohana ka mea kani i ka 7.0-inch 1024 × 600 kiʻekiʻe-definition pale, paʻi hana, ʻike maopopo i ke ao a me ka pō, nā papa kuhikuhi Kina, maʻalahi e hana.
    4. Ua kūkulu ka mea hana i ka hoʻomanaʻo non-volatile nui: hiki iā ia ke mālama i nā pūʻulu 200 o nā ʻikepili ana. Ua lako ka mea hana me ka U-disk interface, hiki ke mālama i kekahi pūʻulu o nā ʻikepili ana (palena ʻia e ka hiki o ka U-disk).
    5. Ua kūkulu ka mea kani i ka hana kiʻekiʻe o ka manawa maoli: hiki ke hana i ka calibration i ka lā a me ka manawa.
    6. Hele mai ka mea kani me kahi mīkini paʻi wela micro-wikiwiki: hiki iā ia ke paʻi i ke ana a me ka ʻikepili mōʻaukala.

 

Laina Huahana 

 

Volta ho'āʻo

AC 100V ±10%, 50Hz

AC 40V±10%, 50Hz

AC 10V±10%, 50Hz

AC 1V±10%, 50Hz

Ke ana ʻana a me ka pololei

Laulā capacitance hiki ke ana

0.1uF~6000uF ±(heluhelu 1%+0.01uF)

Laulā inductance hiki ke ana

50uH ~20H ± (heluhelu 3%+0.05uH)

Hiki ke ana i keia manawa

5mA ~ 2A ±(3% o ka heluhelu + 0.05mA)

Laulā kūʻē hiki ke ana

20mΩ~20kΩ ± (heluhelu 3%+0.1mΩ)

Anana

365mm×285mm×170mm

Ka wela ambient

-20℃~40℃

ʻO ka haʻahaʻa haʻahaʻa

≤85%RH

Mana hana

AC220V±10%, 50±1Hz

 

wikiō

 

Inā makemake ʻoe i kā mākou huahana, hiki iā ʻoe ke koho e waiho i kāu ʻike ma aneʻi, a e hoʻopili koke mākou iā ʻoe.


E kākau i kāu leka ma aneʻi a hoʻouna mai iā mākou
Pili Nūhou
  • Testing Equipment Industry Sees Major Advancements in 2025: Smart & Precision Technologies Lead the Way
    Testing Equipment Industry Sees Major Advancements in 2025: Smart & Precision Technologies Lead the Way
    Release Date: June 6, 2025 As intelligent manufacturing and quality-driven strategies continue to reshape global industries, the testing equipment sector is experiencing a rapid evolution in 2025. Recent updates in national policy, technology innovation, and industrial demand are driving the industry to new heights.
    kikoʻī
  • Applications of Direct Current Generators in Renewable Energy Systems
    Applications of Direct Current Generators in Renewable Energy Systems
    The global shift toward sustainable energy has amplified the demand for efficient power generation and monitoring tools.
    kikoʻī
  • Hipot Tester Calibration and Accuracy Guidelines
    Hipot Tester Calibration and Accuracy Guidelines
    For businesses involved in large-scale electrical infrastructure, maintaining the reliability of testing equipment is non-negotiable.
    kikoʻī

Inā makemake ʻoe i kā mākou huahana, hiki iā ʻoe ke koho e waiho i kāu ʻike ma aneʻi, a e hoʻopili koke mākou iā ʻoe.