PS-9001 Gas Chromatograph

Hiki ke hoʻolako ʻia ka chromatograph gas PS-9001 me nā ʻano mea ʻike like ʻole e hoʻokō i nā pono loiloi o nā kahua like ʻole. He kūpono ka hoʻolālā inlet alakaʻi no nā ʻano laʻana like ʻole, e like me ke ʻano headspace sampling, thermal desorption sampling, a me nā mea ʻē aʻe.
IHO IHO I KA PDF
Nā kikoʻī
Nā huaʻōlelo

gas chromatography gas

Huahana Kūʻai Point Introduction

 

 

1, Nui ʻano o nā ʻāpana detector
Hiki ke hoʻolako ʻia me nā ʻano mea ʻike like ʻole e hoʻokō i nā pono loiloi o nā kahua like ʻole. He kūpono ka hoʻolālā awa hoʻoheheʻe alakaʻi no nā ʻano laʻana like ʻole, e like me ka laʻana headspace, thermal analysis sampling, a me nā mea ʻē aʻe, a hiki ke maʻalahi ke nānā i nā ʻano laʻana.

2, ʻIke ikaika i kāna hana hoʻonui
Hoʻohana ka mea ʻike a me kāna mau mea hoʻomalu i kahi hoʻolālā hui pū ʻia, a ʻo ka ʻōnaehana hoʻokele hoʻonui ʻia he plug-and-play.

3, Ultra-efficient hope hoʻolālā puka
ʻO ka ʻōnaehana hoʻomalu wela o ka puka puka naʻauao e hōʻoia i ka paʻa o ka mahana o ke kolamu ma kekahi wahi, a wikiwiki ka wikiwiki o ka hoʻoilo, hiki ke ʻike i ka hana maoli kokoke i ka lumi wela.
Loaʻa iā ia kahi hana hoʻomaʻamaʻa ponoʻī i ka wā e hoʻomaka ai, hōʻike intuitive o ka ʻike hewa, ka mana o ka mālama ʻana i ka mālama ʻana i ka mana, ka pale pale pale a me ka hiki ke hoʻopilikia i ka mana.

Nā ʻāpana ʻenehana

 

- Wahi hoʻomalu wela: ʻōnaehana hoʻomalu wela kūʻokoʻa kūʻokoʻa 8, me ka hana pale wela ʻakomi, hiki ke hoʻonohonoho ʻia kahi wahi hoʻomehana ʻumu kolamu liʻiliʻi.
- Ka nui o ka pale: 7-inihi kala LCD pale
- 'Ōlelo: Chinese/English ʻelua ʻōnaehana hana
- Column box, gasification chamber, detector temperature range: room temperature +5°C ~ 450°C
- Temperature setting accuracy: 0.1°C
- Maximum heating rate: 80°C/min
- Cooling speed: from 350°C to 50°C<5min
- Puka hope naʻauao: hoʻololi stepless o ka nui o ka ea i loko a i waho
- Ke kauoha hoʻomehana papahana: 16 kauoha (hoʻonui)
- ʻO ka manawa holo lōʻihi loa: 999.99min
- Injection mode: capillary column split/splitless injection (with diaphragm purge function),  - packed column injection, valve injection, gas/liquid automatic sampling system, etc.
- Injection valve: Hiki ke hoʻolako ʻia me nā kīwaha hoʻokele maʻalahi no ka hana ʻana i ka hana
- Ka helu o nā mea ʻike: 4
- ʻAno ʻike: FID, TCD, ECD, FPD, NPD, PDHID, PED, etc.

 

ʻImi ʻAla ʻAla (FID)
Minimum detection limit: ≤3.0*10-12g/s (n-hexadecane/isooctane)
Dynamic linear range: ≥107
Me ka ʻike ahi a me ka hana hoʻāla hou
Kaapuni logarithmic amplifier ākea e hoʻomaikaʻi i ka laulā laina

 

 

Mea ʻimi hoʻoheheʻe wela (TCD)

Sensitivity: ≥10000mv.mL/mg (benzene/toluene)
Dynamic linear range: ≥105
ʻO ka hoʻolālā micro-cavity, ka leo make liʻiliʻi, ka ʻike kiʻekiʻe, me ka hana pale ʻoki kinoea

 

 

Mea ʻimi kiʻi kiʻi ahi (FPD)

Minimum detection limit: S≤2×10-11 g/s (methyl parathion)
P≤1×10-12 g/s (methyl parathion)
Dynamic linear range: S≥103; P≥104
Hoʻopau piha ʻia ka pipeline kūloko, ʻaʻohe wahi anu no ka phosphorus organik

Inā makemake ʻoe i kā mākou huahana, hiki iā ʻoe ke koho e waiho i kāu ʻike ma aneʻi, a e hoʻopili koke mākou iā ʻoe.


E kākau i kāu leka ma aneʻi a hoʻouna mai iā mākou
Pili Nūhou
  • Testing Equipment Industry Sees Major Advancements in 2025: Smart & Precision Technologies Lead the Way
    Testing Equipment Industry Sees Major Advancements in 2025: Smart & Precision Technologies Lead the Way
    Release Date: June 6, 2025 As intelligent manufacturing and quality-driven strategies continue to reshape global industries, the testing equipment sector is experiencing a rapid evolution in 2025. Recent updates in national policy, technology innovation, and industrial demand are driving the industry to new heights.
    kikoʻī
  • Applications of Direct Current Generators in Renewable Energy Systems
    Applications of Direct Current Generators in Renewable Energy Systems
    The global shift toward sustainable energy has amplified the demand for efficient power generation and monitoring tools.
    kikoʻī
  • Hipot Tester Calibration and Accuracy Guidelines
    Hipot Tester Calibration and Accuracy Guidelines
    For businesses involved in large-scale electrical infrastructure, maintaining the reliability of testing equipment is non-negotiable.
    kikoʻī

Inā makemake ʻoe i kā mākou huahana, hiki iā ʻoe ke koho e waiho i kāu ʻike ma aneʻi, a e hoʻopili koke mākou iā ʻoe.