Englesch


Afrikaans
Albanian
Amharic
Arabic
Armenian
Azerbaijani
Basque
Belarusian
Bengali
Bosnian
Bulgarian
Catalan
Cebuano
China
China (Taiwan)
Corsican
Croatian
Czech
Danish
Dutch
English
Esperanto
Estonian
Finnish
French
Frisian
Galician
Georgian
German
Greek
Gujarati
Haitian Creole
hausa
hawaiian
Hebrew
Hindi
Miao
Hungarian
Icelandic
igbo
Indonesian
irish
Italian
Japanese
Javanese
Kannada
kazakh
Khmer
Rwandese
Korean
Kurdish
Kyrgyz
Lao
Latin
Latvian
Lithuanian
Luxembourgish
Macedonian
Malgashi
Malay
Malayalam
Maltese
Maori
Marathi
Mongolian
Myanmar
Nepali
Norwegian
Norwegian
Occitan
Pashto
Persian
Polish
Portuguese
Punjabi
Romanian
Russian
Samoan
Scottish Gaelic
Serbian
Sesotho
Shona
Sindhi
Sinhala
Slovak
Slovenian
Somali
Spanish
Sundanese
Swahili
Swedish
Tagalog
Tajik
Tamil
Tatar
Telugu
Thai
Turkish
Turkmen
Ukrainian
Urdu
Uighur
Uzbek
Vietnamese
Welsh
Bantu
Yiddish
Yoruba
Zulu 
1, Breet Varietéit vun Detektor Eenheeten
Et kann mat enger Vielfalt vun Detektoren ausgestatt sinn fir d'Analysebedürfnisser vu verschiddene Felder z'erreechen. De féierende Injektiounsportdesign ass gëeegent fir eng Vielfalt vu Probemethoden, sou wéi Headspace-Sampling, thermesch Analyse-Sampling, etc., an ass einfach fäeg verschidde Proben ze analyséieren.
2, Mächteg Detektioun vu senger Extensiounsfunktioun
Den Detektor a seng Kontrollkomponenten adoptéieren e vereenegt Kombinatiounsdesign, an den erweiderten Kontrollmodus System ass Plug-and-Play.
3, Ultra-efficace hënneschter Dier Design
D'intelligent hënneschter Dier Temperatur Kontroll System suergt d'Stabilitéit vun der Kolonn Chamber Temperatur an all Beräich, an der Ofkillung Vitesse ass séier, déi real no bei Raumtemperatur Operatioun realiséieren kann.
Et huet eng mächteg Selbstdiagnosfunktioun beim Start, intuitiv Affichage vu Feelerinformatioun, Stroumausfallspeicherschutzfunktioun, automateschen Bildschirmspär an Anti-Kraaftinterferenzfäegkeet.
- Temperaturkontrollberäich: 8-Wee onofhängeg Temperaturkontrollsystem, mat automatescher Temperaturschutzfunktioun, onofhängeg kleng Kolonnofen Heizberäich kann agestallt ginn
- Écran Gréisst: 7-Zoll industriell Faarf LCD Écran
- Sprooch: Chinesesch / Englesch zwee Betribssystemer
- Column box, gasification chamber, detector temperature range: room temperature +5°C ~ 450°C
- Temperature setting accuracy: 0.1°C
- Maximum heating rate: 80°C/min
- Cooling speed: from 350°C to 50°C<5min
- Intelligent hënneschter Dier: Schrëttlos Upassung vum Loftvolumen an eraus
- Programm Heizung Uerdnung: 16 Uerdnung (erweiderbar)
- Déi längste Lafzäit: 999.99min
- Injection mode: capillary column split/splitless injection (with diaphragm purge function), - packed column injection, valve injection, gas/liquid automatic sampling system, etc.
- Injektiounsventil: Et kann mat multiple automatesche Kontrollventile fir automatesch Sequenzbetrieb ausgestatt sinn
- Unzuel vun Detektoren: 4
- Detektortyp: FID, TCD, ECD, FPD, NPD, PDHID, PED, etc.
Waasserstoff Flamdetektor (FID)
Minimum detection limit: ≤3.0*10-12g/s (n-hexadecane/isooctane)
Dynamic linear range: ≥107
Mat Feierdetektioun an automatescher Zündungsfunktioun
Wide-range logarithmic amplifier Circuit fir d'linear Gamme ze verbesseren
Thermal Conductivity Detector (TCD)
Sensitivity: ≥10000mv.mL/mg (benzene/toluene)
Dynamic linear range: ≥105
Mikro-Kavitéit Design, kleng Doudeger Volumen, héich Empfindlechkeet, mat Gas ofgeschnidden Schutz Funktioun
Flame Photometric Detector (FPD)
Minimum detection limit: S≤2×10-11 g/s (methyl parathion)
P≤1×10-12 g/s (methyl parathion)
Dynamic linear range: S≥103; P≥104
Déi intern Pipeline ass voll passivéiert, an et gëtt keng kal Plaz fir organesch Phosphor
gas chromatography gas
gas chromatography gc ms
gas chromatography method
gas chromatography price
gas chromatography products
gas chromatography supplier
gas chromatography supplies
gas chromatography system
gas chromatography test
gc chromatography
gc gas chromatography
gc gcms