EnglishIgilisi

PS-9001 Gas Chromatograph

O le PS-9001 gas chromatograph e mafai ona faʻapipiʻiina i le tele o faʻamatalaga e faʻafetaui ai manaʻoga auiliiliga o fanua eseese. O le taʻitaʻia o le inlet design e talafeagai mo le tele o auala faʻataʻitaʻiga, e pei o le sampling headspace, faʻataʻitaʻiga faʻamaʻi vevela, ma isi, ma e faigofie ona agavaa Suʻesuʻega o faʻataʻitaʻiga eseese.
FA'ATA'U I lalo i le PDF
Fa'amatalaga
Fa'ailoga

gas chromatography gas

Oloa Fa'atauga Fa'atomuaga

 

 

1, Tele ituaiga eseese o vaega detector
E mafai ona faʻapipiʻiina i le tele o faʻamatalaga e faʻafetaui ai manaʻoga o suʻesuʻega o fanua eseese. O le taʻitaʻia o le faʻaogaina o le taulaga e fetaui lelei mo le tele o auala faʻataʻitaʻiga, e pei o le faʻataʻitaʻiga o ulu, faʻataʻitaʻiga suʻesuʻega vevela, ma isi, ma e faigofie ona mafai ona suʻeina faʻataʻitaʻiga eseese.

2, Su'esu'ega malosi o lona fa'aopoopoga galuega
O le mea e iloa ai ma ona vaega fa'atonutonu e fa'aaogaina se mamanu tu'ufa'atasi, ma o le fa'alauteleina o le faiga fa'atonutonu e fa'apipi'i-ma-ta'alo.

3, Fuafuaga pito i tua e sili ona lelei
Le atamai pito i tua faiga pulea vevela e mautinoa ai le mautu o le vevela potu koluma i so o se vaega, ma o le saoasaoa cooling e vave, lea e mafai ona iloa le moni e latalata i le faagaoioiga vevela potu.
O lo'o i ai se galuega mamana fa'apitoa mo le su'esu'eina o le tagata lava ia pe a amata, fa'aaliga fa'apitoa o fa'amatalaga fa'aletonu, fa'aogaina o le puipuiga o le fa'aogaina o le eletise, fa'apolopolo mata otometi ma le malosi fa'alavelave fa'alavelave.

Vaega Fa'atekinisi

 

- Fa'atonuga o le vevela: 8-auala tuto'atasi le fa'atonutonuina o le vevela, fa'atasi ai ma galuega puipuia o le vevela otometi, e mafai ona fa'atutu le vaega fa'avevela o le ogaumu koluma laiti.
- Tele mata: 7-inisi fale gaosi lanu mata LCD
- Gagana: Saina/Igilisi lua faiga fa'aoga
- Column box, gasification chamber, detector temperature range: room temperature +5°C ~ 450°C
- Temperature setting accuracy: 0.1°C
- Maximum heating rate: 80°C/min
- Cooling speed: from 350°C to 50°C<5min
- Faitotoa pito i tua: fetuutuuna'i e aunoa ma se laasaga o le leo o le ea i totonu ma fafo
- Polokalama fa'avevela fa'atonuga: 16 poloaiga (fa'alautele)
- Le umi ole ta'aloga: 999.99min
- Injection mode: capillary column split/splitless injection (with diaphragm purge function),  - packed column injection, valve injection, gas/liquid automatic sampling system, etc.
- Inject valve: E mafai ona faʻapipiʻiina i le tele o vaʻa faʻatonu mo le faʻasologa otometi
- Numera o fa'amatalaga: 4
- Ituaiga Su'esu'e: FID, TCD, ECD, FPD, NPD, PDHID, PED, ma isi.

 

Su'esu'e Afi (FID)
Minimum detection limit: ≤3.0*10-12g/s (n-hexadecane/isooctane)
Dynamic linear range: ≥107
Fa'atasi ai ma le su'esu'eina o le afi ma le fa'aogaina otometi
Lava-lautele logarithmic amplifier circuit e faaleleia ai le laina laina

 

 

Su'esu'ega Fa'avevela (TCD)

Sensitivity: ≥10000mv.mL/mg (benzene/toluene)
Dynamic linear range: ≥105
Fuafuaga micro-cavity, voluma mate laiti, maaleale maualuga, ma le kesi tipi-off galuega puipuia

 

 

Su'esu'e Ata Fua (FPD)

Minimum detection limit: S≤2×10-11 g/s (methyl parathion)
P≤1×10-12 g/s (methyl parathion)
Dynamic linear range: S≥103; P≥104
O le paipa i totonu ua matua pasi, ma e leai se mea malulu mo phosphorus organic

gas chromatography gas

gas chromatography gc ms

gas chromatography method

gas chromatography price

gas chromatography products

gas chromatography supplier

gas chromatography supplies

gas chromatography system

gas chromatography test

gc chromatography

gc gas chromatography

gc gcms

Afai e te fiafia i a matou oloa, e mafai ona e filifili e tuʻu lau faʻamatalaga iinei, ma o le a matou fesoʻotaʻi ma oe i se taimi lata mai.


Tusi lau savali iinei ma lafo mai ia i matou
Fa'atatau Tala Fou
  • Find the Best Loop Impedance Tester for Sale and Ensure Electrical Safety
    Find the Best Loop Impedance Tester for Sale and Ensure Electrical Safety
    When ensuring electrical safety, accurate loop impedance testing is crucial. Whether you’re an electrician, a facilities manager, or a safety inspector, having a reliable loop impedance tester for sale is essential. This article will guide you through the key considerations when purchasing a loop impedance tester, explore the different types available, and highlight the benefits of choosing a high-quality instrument. Understanding the nuances of these testers will help you make an informed decision and ensure compliance with safety regulations.
    Fa'amatalaga
  • Comprehensive Guide to Loop Impedance Meter for Electrical Safety
    Comprehensive Guide to Loop Impedance Meter for Electrical Safety
    Ensuring electrical safety is paramount in any installation, and a loop impedance meter is a crucial tool for achieving this. This device measures the total impedance of the earth fault loop, helping to verify that protective devices will operate correctly under fault conditions. In this article, we'll explore what a loop impedance meter is, how it works, its applications, factors influencing measurements, choosing the right meter, and the importance of regular testing. Investing in a quality meter from Push Tester is a step towards safer electrical systems.
    Fa'amatalaga
  • Understanding and Choosing a Line Impedance Tester for Optimal Network Performance
    Understanding and Choosing a Line Impedance Tester for Optimal Network Performance
    In the realm of telecommunications and electrical engineering, maintaining the integrity of transmission lines is paramount. A line impedance tester is a crucial instrument for ensuring optimal signal transmission and preventing costly network disruptions. This article delves into the world of line impedance testing, exploring its importance, applications, types of testers, and what to look for when making a purchase. Ensuring accurate impedance measurements is essential for efficient and reliable network performance. Choosing the right tester can significantly impact troubleshooting speed and the overall quality of your infrastructure. A line impedance tester, also known as a cable impedance analyzer, is a device used to measure the characteristic impedance of coaxial cables, twisted pair cables, and other transmission lines. Impedance, measured in ohms, represents the opposition to the flow of alternating current. Maintaining the correct impedance (typically 50 or 75 ohms) is vital for minimizing signal reflections, ensuring efficient power transfer, and preventing signal degradation. Mismatched impedance can lead to signal loss, ghosting, and reduced network performance. Regular testing helps identify faults and maintain network integrity.
    Fa'amatalaga

Afai e te fiafia i a matou oloa, e mafai ona e filifili e tuʻu lau faʻamatalaga iinei, ma o le a matou fesoʻotaʻi ma oe i se taimi lata mai.