EnglishTuranci

PS-9001 Gas Chromatograph

PS-9001 chromatograph gas za a iya sanye shi da nau'ikan na'urori daban-daban don saduwa da bukatun bincike na filayen daban-daban. Babban ƙira na mashigai ya dace da nau'ikan samfura iri-iri, irin su samfuran sararin sama, samfurin ɓarkewar zafi, da sauransu, kuma yana da sauƙin ƙware Analysis na samfurori daban-daban.
KYAUTA ZUWA PDF
Cikakkun bayanai
Tags

gas chromatography gas

Gabatarwar Wurin Siyar da Samfura

 

 

1, Faɗin nau'ikan abubuwan ganowa
Ana iya sanye shi da na'urori daban-daban don saduwa da buƙatun bincike na fannoni daban-daban. Jagorar ƙirar tashar tashar allurar ta dace da hanyoyin samfuri iri-iri, irin su samfuran sararin sama, samfurin nazarin zafi, da sauransu, kuma yana da sauƙin yin nazarin samfurori daban-daban.

2, Gano mai ƙarfi na aikin haɓakarsa
Mai ganowa da abubuwan sarrafa sa suna ɗaukar ƙirar haɗin haɗin kai, kuma tsawaita tsarin yanayin sarrafawa shine toshe-da-wasa.

3, Zane kofa na baya mai inganci sosai
Tsarin kula da zafin jiki na ƙofar baya mai hankali yana tabbatar da kwanciyar hankali na ɗakin ɗakin ginshiƙi a kowane yanki, kuma saurin sanyi yana da sauri, wanda zai iya gane ainihin aikin zafin jiki na kusa.
Yana da aikin tantance kai mai ƙarfi lokacin farawa, nunin ilhama na bayanan kuskure, aikin kariyar gazawar wutar lantarki, mai adana allo ta atomatik da ikon tsangwama

Ma'aunin Fasaha

 

- Yankin kula da zafin jiki: 8-hanyar tsarin kula da zafin jiki mai zaman kansa, tare da aikin kariyar zafin jiki ta atomatik, ana iya saita ƙaramin ginshiƙi mai ɗorewa na tanda.
- Girman allo: 7-inch launi LCD allon masana'antu
- Harshe: Sinanci/Turanci tsarin aiki biyu
- Column box, gasification chamber, detector temperature range: room temperature +5°C ~ 450°C
- Temperature setting accuracy: 0.1°C
- Maximum heating rate: 80°C/min
- Cooling speed: from 350°C to 50°C<5min
- Ƙofar baya mai hankali: daidaita girman iska a ciki da waje mara motsi
- Tsarin dumama shirin: oda 16 (wanda za'a iya fadada)
- Mafi tsayin lokacin gudu: 999.99min
- Injection mode: capillary column split/splitless injection (with diaphragm purge function),  - packed column injection, valve injection, gas/liquid automatic sampling system, etc.
- Bawul ɗin allura: Ana iya sanye shi da bawul ɗin sarrafawa ta atomatik da yawa don aiki ta atomatik
- Adadin abubuwan ganowa: 4
- Nau'in ganowa: FID, TCD, ECD, FPD, NPD, PDID, PED, da sauransu.

 

Mai Gano Wuta na Hydrogen (FID)
Minimum detection limit: ≤3.0*10-12g/s (n-hexadecane/isooctane)
Dynamic linear range: ≥107
Tare da gano wuta da aikin sake kunnawa ta atomatik
Da'irar amplifier logarithmic mai faɗi don haɓaka kewayon layi

 

 

Mai Neman Haɓaka Ƙarfafawa (TCD)

Sensitivity: ≥10000mv.mL/mg (benzene/toluene)
Dynamic linear range: ≥105
Ƙirƙirar ƙananan rami, ƙaramin mataccen ƙarar, babban hankali, tare da aikin kariyar yanke-kashe gas

 

 

Mai Gano Hoton Hoto (FPD)

Minimum detection limit: S≤2×10-11 g/s (methyl parathion)
P≤1×10-12 g/s (methyl parathion)
Dynamic linear range: S≥103; P≥104
Bututun na ciki ya cika wucewa, kuma babu wuri mai sanyi don sinadarin phosphorus

gas chromatography gas

gas chromatography gc ms

gas chromatography method

gas chromatography price

gas chromatography products

gas chromatography supplier

gas chromatography supplies

gas chromatography system

gas chromatography test

gc chromatography

gc gas chromatography

gc gcms

Idan kuna sha'awar samfuranmu, zaku iya zaɓar barin bayanin ku anan, kuma za mu tuntube ku nan ba da jimawa ba.


Ku rubuta sakonku anan ku aiko mana
Masu alaƙa Labarai
  • Find the Best Loop Impedance Tester for Sale and Ensure Electrical Safety
    Find the Best Loop Impedance Tester for Sale and Ensure Electrical Safety
    When ensuring electrical safety, accurate loop impedance testing is crucial. Whether you’re an electrician, a facilities manager, or a safety inspector, having a reliable loop impedance tester for sale is essential. This article will guide you through the key considerations when purchasing a loop impedance tester, explore the different types available, and highlight the benefits of choosing a high-quality instrument. Understanding the nuances of these testers will help you make an informed decision and ensure compliance with safety regulations.
    Daki-daki
  • Comprehensive Guide to Loop Impedance Meter for Electrical Safety
    Comprehensive Guide to Loop Impedance Meter for Electrical Safety
    Ensuring electrical safety is paramount in any installation, and a loop impedance meter is a crucial tool for achieving this. This device measures the total impedance of the earth fault loop, helping to verify that protective devices will operate correctly under fault conditions. In this article, we'll explore what a loop impedance meter is, how it works, its applications, factors influencing measurements, choosing the right meter, and the importance of regular testing. Investing in a quality meter from Push Tester is a step towards safer electrical systems.
    Daki-daki
  • Understanding and Choosing a Line Impedance Tester for Optimal Network Performance
    Understanding and Choosing a Line Impedance Tester for Optimal Network Performance
    In the realm of telecommunications and electrical engineering, maintaining the integrity of transmission lines is paramount. A line impedance tester is a crucial instrument for ensuring optimal signal transmission and preventing costly network disruptions. This article delves into the world of line impedance testing, exploring its importance, applications, types of testers, and what to look for when making a purchase. Ensuring accurate impedance measurements is essential for efficient and reliable network performance. Choosing the right tester can significantly impact troubleshooting speed and the overall quality of your infrastructure. A line impedance tester, also known as a cable impedance analyzer, is a device used to measure the characteristic impedance of coaxial cables, twisted pair cables, and other transmission lines. Impedance, measured in ohms, represents the opposition to the flow of alternating current. Maintaining the correct impedance (typically 50 or 75 ohms) is vital for minimizing signal reflections, ensuring efficient power transfer, and preventing signal degradation. Mismatched impedance can lead to signal loss, ghosting, and reduced network performance. Regular testing helps identify faults and maintain network integrity.
    Daki-daki

Idan kuna sha'awar samfuranmu, zaku iya zaɓar barin bayanin ku anan, kuma za mu tuntube ku nan ba da jimawa ba.