EnglishLus Askiv

PUSH Electrical PS-KF106V1 Volumetric Trace Moisture Tester

Lub PS-KF106V1 tsis siv neeg thiab ceev Karl Fischer ya raws ntsuas yog ib qho kev ntsuas tsis siv neeg uas siv Karl Fischer volumetric titration method los ntsuas cov dej noo. Cov cuab yeej no yog cov cuab yeej ntsuas dej zoo tshaj plaws rau kev tsim khoom thiab kev tshawb fawb txog kev ua haujlwm. Cov qauv siv tau: ASTM, GB6238, GB11146, GB11133 thiab lwm yam 20 tus qauv hauv tebchaws
DOWNLOAD RAU PDF
Paub meej
Cim npe
Khoom Muag Khoom Taw Qhia

 

  1. 1.Newly ntxiv ceev dripping muaj nuj nqi, siv electrode polarization voltage yuav tswj tau lub dripping ceev, nws tsuas yog siv kaum vib nas this los ntsuas tus qauv;
    2.Qhov tshiab ammeter ntxiv ua rau cov txheej txheem titration ntau intuitive;
    3.Txhua txoj kev ua kua yog ua los ntawm cov ntaub ntawv tshwj xeeb uas muaj kev tiv thaiv corrosion zoo heev, ua kom muaj kev ua haujlwm tsis tu ncua ntev;
    4.Siv lub electrode polarization voltage los txiav txim thiab tso saib cov tshuaj tiv thaiv qhov kawg taw tes thiab txiav lub titration;
    5.Fully kaw system kom tsis txhob infiltration ntawm ib puag ncig noo noo;
    6.Siv qhov kev sim zoo tib yam (hloov) lub raj mis lub kaus mom ua cov khoom sib txuas kom hloov tau yooj yim;
    7.Nias cov yuam sij muaj nuj nqi, thiab cov cuab yeej muaj peev xwm paub tau: qhov nqus nqus nqus nqus, ntsuas, qhov kawg taw tes qhia (alarm), cov kua dej pov tseg, thiab nplawm;
    8.PS-KF106V1 tsis siv neeg ceev ceev Karl Fischer noo noo analyzer txais ib lub raj mis tshwj xeeb reagent connector, uas tuaj yeem siv cov qauv pyridine lossis pyridine-dawb reagents;
    9.PS-KF106V1 tsis siv neeg thiab ceev Karl Fischer ya raws analyzer adopts high-brightness cov raj thiab cov zaub ntshiab;
    10.Thaum lub sijhawm ua haujlwm tsis raug, koj tuaj yeem cuam tshuam tam sim ntawd thiab rov pib ua haujlwm;
    11.Txhim lub kaw lus tsim cov kav dej kom tsis txhob muaj kev khiav tawm ntawm cov pa phem, tiv thaiv ib puag ncig thiab kev noj qab haus huv, thiab cov cuab yeej ua haujlwm zoo thiab tsis muaj suab nrov;

  2. Cov khoom siv:
    Pharmaceuticals, organic chemicals, inorganic chemicals, petrochemicals, chiv, tshuaj tua kab, dyes, coatings, zaub mov thiab dej haus, surfactants, tshuaj pleev ib ce, thiab lwm yam.

 

Khoom Parameters

 

1.Kev ntsuas ntau: 30ppm-100% (H2O pawg pawg)
2.Resolution: 0.01ml
3.Moisture titration repeatability: ≤0.01
4.Linear correlation coefficient ntawm dej titration: ≥0.998
5. Muaj peev xwm yuam kev ≤ ± 0.002
6.Instrument burette muaj peev xwm: ntau dua 25ml
7.Sensitivity: 10-6A

 

Video

 

karl fischer auto titrator

karl fischer moisture titrator

karl fischer volumetric titration

moisture tester

oil moisture tester

transformer oil moisture tester

Yog tias koj txaus siab rau peb cov khoom, koj tuaj yeem xaiv tawm koj cov ntaub ntawv ntawm no, thiab peb yuav tiv tauj koj sai sai.


Sau koj cov lus ntawm no thiab xa tuaj rau peb
Hais txog Xov xwm
  • Find the Best Loop Impedance Tester for Sale and Ensure Electrical Safety
    Find the Best Loop Impedance Tester for Sale and Ensure Electrical Safety
    When ensuring electrical safety, accurate loop impedance testing is crucial. Whether you’re an electrician, a facilities manager, or a safety inspector, having a reliable loop impedance tester for sale is essential. This article will guide you through the key considerations when purchasing a loop impedance tester, explore the different types available, and highlight the benefits of choosing a high-quality instrument. Understanding the nuances of these testers will help you make an informed decision and ensure compliance with safety regulations.
    Paub meej
  • Comprehensive Guide to Loop Impedance Meter for Electrical Safety
    Comprehensive Guide to Loop Impedance Meter for Electrical Safety
    Ensuring electrical safety is paramount in any installation, and a loop impedance meter is a crucial tool for achieving this. This device measures the total impedance of the earth fault loop, helping to verify that protective devices will operate correctly under fault conditions. In this article, we'll explore what a loop impedance meter is, how it works, its applications, factors influencing measurements, choosing the right meter, and the importance of regular testing. Investing in a quality meter from Push Tester is a step towards safer electrical systems.
    Paub meej
  • Understanding and Choosing a Line Impedance Tester for Optimal Network Performance
    Understanding and Choosing a Line Impedance Tester for Optimal Network Performance
    In the realm of telecommunications and electrical engineering, maintaining the integrity of transmission lines is paramount. A line impedance tester is a crucial instrument for ensuring optimal signal transmission and preventing costly network disruptions. This article delves into the world of line impedance testing, exploring its importance, applications, types of testers, and what to look for when making a purchase. Ensuring accurate impedance measurements is essential for efficient and reliable network performance. Choosing the right tester can significantly impact troubleshooting speed and the overall quality of your infrastructure. A line impedance tester, also known as a cable impedance analyzer, is a device used to measure the characteristic impedance of coaxial cables, twisted pair cables, and other transmission lines. Impedance, measured in ohms, represents the opposition to the flow of alternating current. Maintaining the correct impedance (typically 50 or 75 ohms) is vital for minimizing signal reflections, ensuring efficient power transfer, and preventing signal degradation. Mismatched impedance can lead to signal loss, ghosting, and reduced network performance. Regular testing helps identify faults and maintain network integrity.
    Paub meej

Yog tias koj txaus siab rau peb cov khoom, koj tuaj yeem xaiv tawm koj cov ntaub ntawv ntawm no, thiab peb yuav tiv tauj koj sai sai.