Igilisi

PUSH Electrical PS-KF106V1 Volumetric Trace Moisture Tester

O le PS-KF106V1 otometi ma vave Karl Fischer su'esu'e su'esu'e o se meafaigaluega au'ili'ili otometi lea e fa'aogaina ai le Karl Fischer volumetric titration metotia e fua ai le susu. O lenei mea faigaluega o se mea faigaluega susū susū lelei mo le gaosiga ma galuega suʻesuʻe faasaienisi. Tulaga talafeagai: ASTM, GB6238, GB11146, GB11133 ma isi 20 tulaga faʻale-atunuu
FA'ATA'U I lalo i le PDF
Fa'amatalaga
Fa'ailoga
Oloa Fa'atauga Fa'atomuaga

 

  1. 1.Newly faaopoopo faavavevave galuega tauave dripping, faaaogaina electrode polarization voltage e otometi le pulea o le saosaoa dripping, e na o le sefulu o sekone e fua ai se faataitaiga;
    2.O le ammeter fou faaopoopo ua sili atu le malamalama le faagasologa titration;
    3.O le ala vai atoa e faia i mea faʻapitoa faʻatasi ai ma le sili ona lelei le faʻafefeteina, faʻamautinoa le faʻaauauina o le faʻagaioiga umi;
    4. Fa'aaoga le electrode polarization voltage e fa'amasino ma fa'aalia le tali fa'ai'uga ma fa'amutaina le titration;
    5. Fully tapuni faiga e aloese ai mai le infiltration o le susu siosiomaga;
    6. Faʻaaogaina faʻataʻitaʻiga masani (solvent) tapuni fagu e fai ma fesoʻotaʻiga mo le faigofie ona sui;
    7.Press ki galuega tauave talafeagai, ma e mafai ona iloa e le meafaigaluega: inhalation solvent, fuaina, faʻaaliga pito iʻu (talatala), otaota otaota lafoai, ma faʻavevesi;
    8.PS-KF106V1 otometi vave Karl Fischer moisture analyzer faʻaaogaina se faʻafesoʻotaʻi fagu faʻapitoa faʻapitoa, lea e mafai ona faʻaogaina ai le pyridine masani poʻo le pyridine-free reagents;
    9.PS-KF106V1 otometi ma vave Karl Fischer susū analyzer vaetamaina maualuga-malamalama faagaau numera ma faaaliga manino;
    10. O le taimi lava e le saʻo le taotoga, e mafai ona e vave faʻalavelave ma toe amata le gaioiga;
    11. Faʻaaogaina se faiga faʻapipiʻi faʻapipiʻi atoatoa e aloese ai mai le sola ese o kasa oona, puipuia le siosiomaga ma le soifua maloloina, ma le mea faigaluega e sologa lelei ma aunoa ma se pisa;

  2. Mea fa'aoga:
    Pharmaceuticals, organic chemicals, inorganic chemicals, petrochemicals, fertilizers, pesticides, dyes, coatings, food and drinks, surfactants, cosmetics, etc.

 

Fua Fa'atatau

 

1. Measurement range: 30ppm-100% (H2O vaega vaega tele)
2. Resolution: 0.01ml
3.Susu titration toe mafai: ≤0.01
4.Linear correlation coefficient o vai titration: ≥0.998
5. Capacity error≤±0.002
6.Instrument burette gafatia: sili atu i le 25ml
7. Lagona: 10-6A

 

Vitio

 

Afai e te fiafia i a matou oloa, e mafai ona e filifili e tuʻu lau faʻamatalaga iinei, ma o le a matou fesoʻotaʻi ma oe i se taimi lata mai.


Tusi lau savali iinei ma lafo mai ia i matou
Fa'atatau Tala Fou
  • Using Distillation Range Testers in the Food and Beverage Industry
    Using Distillation Range Testers in the Food and Beverage Industry
    The food and beverage industry relies on distillation to refine essential ingredients, from flavor extracts to alcoholic beverages and edible oils.
    Fa'amatalaga
  • The Impact of IoT on Distillation Range Tester Performance
    The Impact of IoT on Distillation Range Tester Performance
    The Internet of Things (IoT) is transforming industries worldwide, and the field of distillation range testing is no exception.
    Fa'amatalaga
  • The Best Distillation Range Testers for Extreme Conditions
    The Best Distillation Range Testers for Extreme Conditions
    In the world of chemical engineering and laboratory testing, precision and reliability are paramount.
    Fa'amatalaga

Afai e te fiafia i a matou oloa, e mafai ona e filifili e tuʻu lau faʻamatalaga iinei, ma o le a matou fesoʻotaʻi ma oe i se taimi lata mai.