EnglishIcyongereza

PS-ZK03 Guhindura Ikizamini kigufi cyumuzenguruko

Inzitizi ngufi-inzitizi ningingo yingenzi ya transformateur, kandi uburyo bwumuzunguruko bugufi nuburyo gakondo bwo gucira imanza ihindagurika. Dukurikije GB1094.5-2003 na IEC60076-5: 2000, itandukaniro ryimikorere yumuzunguruko mugufi nicyo gipimo cyonyine cyo gusuzuma niba guhinduranya transformateur byahinduwe. Ikizamini cya voltage ntoya-yumuzunguruko nuburyo bweruye bwo kugenzura niba guhinduranya byahinduwe nyuma ya transformateur yibasiwe numuyoboro mugari mugihe gikora, cyangwa nyuma ya transformateur ikozwe ningufu za mashini mugihe cyo gutwara no kuyishyiraho. Ni ngombwa gusuzuma niba transformateur ishobora gushyirwa mubikorwa. Ninimwe murwego rwo gusuzuma niba transformateur isaba ubugenzuzi bwo gusenya.
SHAKA UMURONGO Kuri PDF
Ibisobanuro
Etiquetas
Ibicuruzwa byo kugurisha

 

  1. 1. Gupima ibyiciro bitatu bigufi-inzitizi zumuzunguruko:
    Erekana ibyiciro bitatu bya voltage, ibyiciro bitatu, amashanyarazi atatu; mu buryo bwikora kubara ijanisha rya voltage ya impedance yahinduwe mubushyuhe bwagenwe hamwe nigipimo cyagenwe cya transformateur, hamwe nijanisha ryamakosa hamwe nimbogamizi yicyapa.
    2. Gupima icyiciro kimwe kigufi-inzitizi:
    Gupima inzitizi ngufi-inzitizi ya transformateur yicyiciro kimwe.
    3. Gupima inzitizi zikurikiranye:
    Ibipimo bya zeru-zikurikirana impedance ikwiranye na transformateur hamwe ningingo idafite aho ibogamiye mu nyenyeri ihuza uruhande rwinshi rwa voltage.
    4. Irashobora gupimwa muburyo butemewe bwo gupima igikoresho, kandi voltage yo hanze hamwe na transformateur zubu zirashobora guhuzwa hanze yikigereranyo. Igikoresho kirashobora gushiraho igipimo cyimpinduka za voltage yo hanze hamwe na transformateur zubu, kandi ikerekana mu buryo butaziguye imbaraga zikoreshwa n’indangagaciro.
    5. Igikoresho gikoresha ibara rinini-ryerekana ibara ryinshi-rikoraho LCD, menu yubushinwa, ibisobanuro byabashinwa, nibikorwa byoroshye.
    6. Igikoresho kizana printer, ishobora gucapa no kwerekana amakuru.
    7. Yubatswe mububiko butari imbaraga-hasi, irashobora kubika ibice 200 byamakuru yo gupima.
    8. Igikoresho gifite ibikoresho bya U disiki yo kubona amakuru yikizamini.
    9. Kalendari ihoraho, imikorere yisaha, kalibrasi yigihe irashobora gukorwa.
    10. Igikoresho gifite intera nini yo gupima, ibisobanuro bihanitse kandi bihamye; ingano ntoya nuburemere bworoshye kubipima.

 

Ibicuruzwa 

 

Umuvuduko (urwego rwikora)

15 ~ 400V

± (gusoma × 0.2% + imibare 3) ± 0.04% (intera)

Ibiriho (urutonde rwikora)

0.10 ~ 20A

± (gusoma × 0.2% + imibare 3) ± 0.04% (intera)

Imbaraga

COSΦ> 0.15

(Gusoma × 0.5% + Imibare 3)

Inshuro (inshuro nyinshi)

45 ~ 65 (Hz)

Ibipimo bifatika

± 0.1%

Inzitizi ngufi

0 ~ 100%

Ibipimo bifatika

± 0.5%

Subiramo ituze

itandukaniro ryikigereranyo <0.2%, itandukaniro ryinguni <0.02 °

Kwerekana ibikoresho

Imibare 5

Kurinda ibikoresho

Ikizamini cyikigereranyo kirenze 18A, imbere yimbere yigikoresho cyaciwe, kandi uburinzi burenze urugero buratangwa.

Ubushyuhe bwibidukikije

-10 ℃ ~ 40 ℃

Ubushuhe bugereranije

≤ 85% RH

Imbaraga zo gukora

AC 220V ± 10% 50Hz ± 1Hz

Ibipimo

Umucumbitsi

360 * 290 * 170 (mm)

Agasanduku k'insinga

360 * 290 * 170 (mm)

Ibiro

Umucumbitsi

4.85Kg

Agasanduku k'insinga

5.15KG

 

Video

 

cable impedance tester

impedance test of transformer

loop impedance meter

loop impedance tester

loop impedance tester for sale

loop impedance tester price

low impedance tester

short circuit impedance

short circuit impedance of transformer

short circuit impedance test of transformer

short circuit impedance transformer

transformer short circuit impedance test

Niba ushimishijwe nibicuruzwa byacu, urashobora guhitamo gusiga amakuru yawe hano, kandi tuzahuza nawe vuba.


Andika ubutumwa bwawe hano hanyuma utwohereze
Bifitanye isano Amakuru
  • Find the Best Loop Impedance Tester for Sale and Ensure Electrical Safety
    Find the Best Loop Impedance Tester for Sale and Ensure Electrical Safety
    When ensuring electrical safety, accurate loop impedance testing is crucial. Whether you’re an electrician, a facilities manager, or a safety inspector, having a reliable loop impedance tester for sale is essential. This article will guide you through the key considerations when purchasing a loop impedance tester, explore the different types available, and highlight the benefits of choosing a high-quality instrument. Understanding the nuances of these testers will help you make an informed decision and ensure compliance with safety regulations.
    Ibisobanuro
  • Comprehensive Guide to Loop Impedance Meter for Electrical Safety
    Comprehensive Guide to Loop Impedance Meter for Electrical Safety
    Ensuring electrical safety is paramount in any installation, and a loop impedance meter is a crucial tool for achieving this. This device measures the total impedance of the earth fault loop, helping to verify that protective devices will operate correctly under fault conditions. In this article, we'll explore what a loop impedance meter is, how it works, its applications, factors influencing measurements, choosing the right meter, and the importance of regular testing. Investing in a quality meter from Push Tester is a step towards safer electrical systems.
    Ibisobanuro
  • Understanding and Choosing a Line Impedance Tester for Optimal Network Performance
    Understanding and Choosing a Line Impedance Tester for Optimal Network Performance
    In the realm of telecommunications and electrical engineering, maintaining the integrity of transmission lines is paramount. A line impedance tester is a crucial instrument for ensuring optimal signal transmission and preventing costly network disruptions. This article delves into the world of line impedance testing, exploring its importance, applications, types of testers, and what to look for when making a purchase. Ensuring accurate impedance measurements is essential for efficient and reliable network performance. Choosing the right tester can significantly impact troubleshooting speed and the overall quality of your infrastructure. A line impedance tester, also known as a cable impedance analyzer, is a device used to measure the characteristic impedance of coaxial cables, twisted pair cables, and other transmission lines. Impedance, measured in ohms, represents the opposition to the flow of alternating current. Maintaining the correct impedance (typically 50 or 75 ohms) is vital for minimizing signal reflections, ensuring efficient power transfer, and preventing signal degradation. Mismatched impedance can lead to signal loss, ghosting, and reduced network performance. Regular testing helps identify faults and maintain network integrity.
    Ibisobanuro

Niba ushimishijwe nibicuruzwa byacu, urashobora guhitamo gusiga amakuru yawe hano, kandi tuzahuza nawe vuba.