PS-BB102 Transformer ea Mehato e meraro e Fetola Ratio Tester

Teko ea Z-Join Transformer. Ka karo-karolelano ea teko ea bofofu, tlhahlobo ea sehlopha, teko ea boemo ba ho theipi le mesebetsi e meng. Mefuta ea phepelo ea motlakase ea AC/DC e amohetsoe, 'me e ka sebelisoa ka matla kapa ntle le matla a mantlha sebakeng sa marang-rang. Boholo bo nyane, boima bo bobebe, bo bonolo ho jara. Tšireletso ea khokahanyo e phahameng le e tlase ea motlakase. Tšireletso ea potoloho e khuts'oane ea Transformer le ea turn-to-turn-short-circuit.
TS'ELISITSOE PELE PDF
Lintlha
Li-tag
Selelekela sa Ntlha ea ho Rekisa Sehlahisoa

 

  1. 1. Lethathamo la teko le pharaletseng, ho fihla ho 10000.

    2. Lebelo la teko le potlakile, 'me teko ea karolo e le' ngoe e phethoa ka metsotsoana ea 5.

    3. 240 * 128 'mala oa LCD skrine, sebopeho se kopanetsoeng se na le ts'ebetso e hlakileng haholoanyane.

    4. Teko ea transformer ea Z-connection.

    5. E na le mesebetsi e kang teko ea bofofu ea karo-karolelano ea phetoho, tlhahlobo ea sehlopha, le teko ea boemo ba ho pompo.

    6. Pontšo ea oache le letsatsi ntle le ho felloa ke matla, ts'ebetso ea polokelo ea data (lihlopha tsa 50 tsa data ea liteko li ka bolokoa).

    7. Ts'ebetso ea ts'ireletso ea khokahanyo e phahameng le e tlase ea motlakase.

    8. Transformer short circuit le inter-turn short circuit ts'ireletso ea potoloho.

    9. Thermal printer output function, e potlakileng le e khutsitseng.

    10. E sebelisa mokhoa oa phepelo ea motlakase oa AC/DC, 'me e ka sebelisoa ka matla kapa ntle le matla a maholo setšeng.

    11. Boholo bo nyane, boima bo bobebe, bo bonolo ho jara.

 

Litšobotsi tsa Parameter ea Sehlahisoa

 

Range

0.9–10000

Ho nepahala

0.1% ± 2 lipalo (0.9 ~ 500)

0.2% ± 2 lipalo (500 ~ 2000)

0.3% ± 2 lipalo (2000 ~ 4000)

0.5% ± 2 lipalo (4000 holimo)

Matla a ho rarolla

bonyane 0.0001

Matla a tsoang

160V/10V (Autoshift)

Phepelo ea motlakase e sebetsang

Mokhoa oa AC — — Phepelo ea matla a kantle a AC AC220V ± 10%, 50Hz ea hlokahala. (Se ke oa sebelisa jenereithara)

Mokhoa oa DC - - Ha ho na matla a kantle a hlokahalang (sesebelisoa se na le betri ea sona ea lithium)

Mocheso oa tšebeletso

-10℃~40℃

Mongobo o amanang

≤ 80%, ha ho na condensation

 

Video

 

transformer ttr

transformer turns ratio meter

transformer turns ratio test set

transformer turns ratio tester

transformer voltage turns ratio

ttr test

ttr test in transformer

ttr test of power transformer

ttr test of transformer

ttr test set

ttr tester

ttr transformer turns ratio

turns ratio meter

turns ratio test in transformer

turns ratio tester

Haeba u thahasella lihlahisoa tsa rona, u ka khetha ho siea lintlha tsa hau mona, 'me re tla buisana le uena haufinyane.


Ngola molaetsa wa hao mona mme o re romele wona
Tse amanang Litaba
  • Find the Best Loop Impedance Tester for Sale and Ensure Electrical Safety
    Find the Best Loop Impedance Tester for Sale and Ensure Electrical Safety
    When ensuring electrical safety, accurate loop impedance testing is crucial. Whether you’re an electrician, a facilities manager, or a safety inspector, having a reliable loop impedance tester for sale is essential. This article will guide you through the key considerations when purchasing a loop impedance tester, explore the different types available, and highlight the benefits of choosing a high-quality instrument. Understanding the nuances of these testers will help you make an informed decision and ensure compliance with safety regulations.
    Lintlha
  • Comprehensive Guide to Loop Impedance Meter for Electrical Safety
    Comprehensive Guide to Loop Impedance Meter for Electrical Safety
    Ensuring electrical safety is paramount in any installation, and a loop impedance meter is a crucial tool for achieving this. This device measures the total impedance of the earth fault loop, helping to verify that protective devices will operate correctly under fault conditions. In this article, we'll explore what a loop impedance meter is, how it works, its applications, factors influencing measurements, choosing the right meter, and the importance of regular testing. Investing in a quality meter from Push Tester is a step towards safer electrical systems.
    Lintlha
  • Understanding and Choosing a Line Impedance Tester for Optimal Network Performance
    Understanding and Choosing a Line Impedance Tester for Optimal Network Performance
    In the realm of telecommunications and electrical engineering, maintaining the integrity of transmission lines is paramount. A line impedance tester is a crucial instrument for ensuring optimal signal transmission and preventing costly network disruptions. This article delves into the world of line impedance testing, exploring its importance, applications, types of testers, and what to look for when making a purchase. Ensuring accurate impedance measurements is essential for efficient and reliable network performance. Choosing the right tester can significantly impact troubleshooting speed and the overall quality of your infrastructure. A line impedance tester, also known as a cable impedance analyzer, is a device used to measure the characteristic impedance of coaxial cables, twisted pair cables, and other transmission lines. Impedance, measured in ohms, represents the opposition to the flow of alternating current. Maintaining the correct impedance (typically 50 or 75 ohms) is vital for minimizing signal reflections, ensuring efficient power transfer, and preventing signal degradation. Mismatched impedance can lead to signal loss, ghosting, and reduced network performance. Regular testing helps identify faults and maintain network integrity.
    Lintlha

Haeba u thahasella lihlahisoa tsa rona, u ka khetha ho siea lintlha tsa hau mona, 'me re tla buisana le uena haufinyane.