EnglishSaesneg

Mae trawsnewidydd tri cham PS-BB102 yn Troi Profwr Cymhareb

Z-Ymunwch â Phrawf Trawsnewidydd. Gyda chymhareb prawf dall, prawf grŵp, prawf sefyllfa tap a swyddogaethau eraill. Mae moddau cyflenwad pŵer AC/DC yn cael eu mabwysiadu, a gellir ei ddefnyddio gyda neu heb brif gyflenwad pŵer ar y safle. Maint bach, pwysau ysgafn, hawdd i'w gario. Amddiffyniad cysylltiad gwrthdroi foltedd uchel ac isel. Trawsnewidydd cylched byr a tro-i-droi amddiffyn cylched byr.
LLWYTH I LAWR I PDF
Manylion
Tagiau
Cyflwyniad Pwynt Gwerthu Cynnyrch

 

  1. 1. Mae'r ystod prawf yn eang, hyd at 10000.

    2. Mae cyflymder y prawf yn gyflym, a chwblheir y prawf un cam o fewn 5 eiliad.

    3. Sgrin LCD lliw 240 * 128, mae'r rhyngwyneb rhyngweithiol yn fwy sythweledol.

    4. Z-cysylltiad trawsnewidydd prawf.

    5. Mae ganddo swyddogaethau megis prawf dall o gymhareb trawsnewid, prawf grŵp, a phrawf sefyllfa tap.

    6. Arddangosfa cloc a dyddiad heb fethiant pŵer, swyddogaeth storio data (gellir storio 50 grŵp o ddata prawf).

    7. Swyddogaeth amddiffyn cysylltiad gwrthdroi foltedd uchel ac isel.

    8. cylched byr trawsnewidydd a swyddogaeth amddiffyn cylched byr rhyng-dro.

    9. Swyddogaeth allbwn argraffydd thermol, yn gyflym ac yn dawel.

    10. Mae'n mabwysiadu modd cyflenwad pŵer AC/DC, a gellir ei ddefnyddio gyda neu heb bŵer prif gyflenwad ar y safle.

    11. Maint bach, pwysau ysgafn, hawdd i'w gario.

 

Nodweddion Paramedr Cynnyrch

 

Amrediad

0.9 ~ 10000

Cywirdeb

0.1% ±2 rhifol (0.9 ~ 500 )

0.2% ±2 rhifol (500 ~ 2000)

0.3% ±2 rhifol (2000 ~ 4000)

0.5% ±2 rhifol (4000 uchod)

Datrys pŵer

lleiafswm 0.0001

Foltedd allbwn

160V/10V (Awtosymud)

Cyflenwad pŵer gweithio

Modd AC —— Mae angen cyflenwad pŵer AC allanol AC220V ± 10%, 50Hz. (Peidiwch â defnyddio'r generadur)

Modd DC —— Nid oes angen cyflenwad pŵer allanol (mae gan yr offeryn ei batri lithiwm ei hun)

Tymheredd gwasanaeth

-10 ℃ ~ 40 ℃

Lleithder cymharol

≤ 80%, dim anwedd

 

Fideo

 

transformer ttr

transformer turns ratio meter

transformer turns ratio test set

transformer turns ratio tester

transformer voltage turns ratio

ttr test

ttr test in transformer

ttr test of power transformer

ttr test of transformer

ttr test set

ttr tester

ttr transformer turns ratio

turns ratio meter

turns ratio test in transformer

turns ratio tester

Os oes gennych ddiddordeb yn ein cynnyrch, gallwch ddewis gadael eich gwybodaeth yma, a byddwn yn cysylltu â chi yn fuan.


Ysgrifennwch eich neges yma a'i hanfon atom
Cysylltiedig Newyddion
  • Find the Best Loop Impedance Tester for Sale and Ensure Electrical Safety
    Find the Best Loop Impedance Tester for Sale and Ensure Electrical Safety
    When ensuring electrical safety, accurate loop impedance testing is crucial. Whether you’re an electrician, a facilities manager, or a safety inspector, having a reliable loop impedance tester for sale is essential. This article will guide you through the key considerations when purchasing a loop impedance tester, explore the different types available, and highlight the benefits of choosing a high-quality instrument. Understanding the nuances of these testers will help you make an informed decision and ensure compliance with safety regulations.
    Manylyn
  • Comprehensive Guide to Loop Impedance Meter for Electrical Safety
    Comprehensive Guide to Loop Impedance Meter for Electrical Safety
    Ensuring electrical safety is paramount in any installation, and a loop impedance meter is a crucial tool for achieving this. This device measures the total impedance of the earth fault loop, helping to verify that protective devices will operate correctly under fault conditions. In this article, we'll explore what a loop impedance meter is, how it works, its applications, factors influencing measurements, choosing the right meter, and the importance of regular testing. Investing in a quality meter from Push Tester is a step towards safer electrical systems.
    Manylyn
  • Understanding and Choosing a Line Impedance Tester for Optimal Network Performance
    Understanding and Choosing a Line Impedance Tester for Optimal Network Performance
    In the realm of telecommunications and electrical engineering, maintaining the integrity of transmission lines is paramount. A line impedance tester is a crucial instrument for ensuring optimal signal transmission and preventing costly network disruptions. This article delves into the world of line impedance testing, exploring its importance, applications, types of testers, and what to look for when making a purchase. Ensuring accurate impedance measurements is essential for efficient and reliable network performance. Choosing the right tester can significantly impact troubleshooting speed and the overall quality of your infrastructure. A line impedance tester, also known as a cable impedance analyzer, is a device used to measure the characteristic impedance of coaxial cables, twisted pair cables, and other transmission lines. Impedance, measured in ohms, represents the opposition to the flow of alternating current. Maintaining the correct impedance (typically 50 or 75 ohms) is vital for minimizing signal reflections, ensuring efficient power transfer, and preventing signal degradation. Mismatched impedance can lead to signal loss, ghosting, and reduced network performance. Regular testing helps identify faults and maintain network integrity.
    Manylyn

Os oes gennych ddiddordeb yn ein cynnyrch, gallwch ddewis gadael eich gwybodaeth yma, a byddwn yn cysylltu â chi yn fuan.