EnglishPelekania
phone
Kelepona:0312-3189593

ʻO PS-CTPT1000 ka hoʻololi pinepine ʻana i ka mea hōʻike Ct Pt

Hoʻohana ka mea hana i ka DSP a me ka ARM kiʻekiʻe, a me ka ʻenehana hana kiʻekiʻe e hōʻoia i ka hana paʻa a me ka hilinaʻi o ka huahana, nā hana piha, ka automation kiʻekiʻe, ka maikaʻi o ka hoʻāʻo kiʻekiʻe, a me kahi pae alakaʻi i ka ʻāina. He mea hana hoʻāʻo ʻoihana no nā mea hoʻololi i ka ʻoihana mana.
IHO IHO I KA PDF
Nā kikoʻī
Nā huaʻōlelo
Huahana Kūʻai Point Introduction

 

  1. 1、ʻO nā hana piha, ʻaʻole i hoʻokō wale i nā hiʻohiʻona excitation (ʻo ia hoʻi nā hiʻohiʻona volt-ampere), ka hoʻololi ʻana, ka polarity, ke kūpaʻa ʻana o ka lua, ka ukana lua, ka ʻokoʻa ratio, a me ka ʻokoʻa ʻokoʻa o nā CT like ʻole (e like me ka pale, ke ana, TP) Hiki ke hoʻohana ʻia no ka hoʻāʻo ʻana i nā hiʻohiʻona excitation, transformation ratio, polarity, second winding resistance, ratio difference a me ke kihi ʻokoʻa o nā ʻāpana electromagnetic PT.
    2、ʻO ka helu inflection voltage/i kēia manawa, 10% (5%) kuhi hewa, ka helu palena pololei (ALF), ka mea palekana mea hana (FS), ka manawa lua (Ts), ka helu remanence (Kr), ka saturation a me ka CT a me PT nā ʻāpana e like me ka unsaturated inductance.
    3、Ua hui ka ho'āʻo i nā kūlana transformer like ʻole GB1208 (IEC60044-1), GB16847 (IEC60044-6), GB1207, a me nā mea ʻē aʻe, a ʻo ia ka mea i koho ʻia no ka hoʻāʻo ʻana e like me ke ʻano a me ka pae o ka transformer.
    4、Ma muli o ke ʻano hoʻāʻo haʻahaʻa haʻahaʻa haʻahaʻa kiʻekiʻe, hiki iā ia ke hoʻokō me ka hoʻāʻo CT me kahi helu inflection a hiki i 45KV.
    5、Maikaʻi a nani hoʻi, nā kiʻi kiʻi Kina āpau.
    6、Hiki i ka hāmeʻa ke mālama i 2000 mau ʻikepili hoʻāʻo, ʻaʻole e nalowale ma hope o ka pau ʻole o ka mana. Ma hope o ka pau ʻana o ka hoʻāʻo ʻana, e mālama iā ia ma ka PC me kahi disk U, hoʻopili i ka ʻikepili me ka polokalamu, a hana i kahi hōʻike WORD.
    7、 He maʻalahi a maʻalahi ka hoʻāʻo. Hiki ke hoʻopau ʻia ke kī kū hoʻokahi, ka hoʻoulu ʻana, ka lakene hoʻololi a me ka polarity test o CT. Ma waho aʻe o ka hoʻāʻo ʻana, hoʻohana nā hoʻokolohua CT ʻē aʻe i ke ʻano wili like.
    8、E maʻalahi ke lawe, ʻo ke kaumaha o ka hāmeʻa he <9Kg.

 

Laina Huahana 

 

Manaʻo hoʻāʻo

Papa pale CT, papa pale PT

Hoʻopuka

0~180Vrms,12Arms,18A(Peak)

Lakiō CT
Ana ana

ʻĀpana

1~40000

 

Ka pololei

±0.05%

ratio PT
Ana ana

ʻĀpana

1~40000

 

Ka pololei

±0.05%

Ana pae

Ka pololei

±5min

 

Olelo Hooholo

0.5min

Ana kū'ē wili lua

ʻĀpana

0~300Ω

 

Ka pololei

2%±2mΩ

Ana kau ukana AC

ʻĀpana

0~1000VA

 

Ka pololei

2%±0.2VA

Volta hoʻokomo mana hoʻokomo

AC220V±10%,50Hz

kaiapuni hana

mahana:-10°C~50°C, haʻahaʻa:≤90%

nui a me ke kaumaha

Nui:340mm x 300mm x 150mm kaumaha:<9kg

 

wikiō

 

ct pt testing equipment

Inā makemake ʻoe i kā mākou huahana, hiki iā ʻoe ke koho e waiho i kāu ʻike ma aneʻi, a e hoʻopili koke mākou iā ʻoe.


E kākau i kāu leka ma aneʻi a hoʻouna mai iā mākou
Pili Nūhou
  • Find the Best Loop Impedance Tester for Sale and Ensure Electrical Safety
    Find the Best Loop Impedance Tester for Sale and Ensure Electrical Safety
    When ensuring electrical safety, accurate loop impedance testing is crucial. Whether you’re an electrician, a facilities manager, or a safety inspector, having a reliable loop impedance tester for sale is essential. This article will guide you through the key considerations when purchasing a loop impedance tester, explore the different types available, and highlight the benefits of choosing a high-quality instrument. Understanding the nuances of these testers will help you make an informed decision and ensure compliance with safety regulations.
    kikoʻī
  • Comprehensive Guide to Loop Impedance Meter for Electrical Safety
    Comprehensive Guide to Loop Impedance Meter for Electrical Safety
    Ensuring electrical safety is paramount in any installation, and a loop impedance meter is a crucial tool for achieving this. This device measures the total impedance of the earth fault loop, helping to verify that protective devices will operate correctly under fault conditions. In this article, we'll explore what a loop impedance meter is, how it works, its applications, factors influencing measurements, choosing the right meter, and the importance of regular testing. Investing in a quality meter from Push Tester is a step towards safer electrical systems.
    kikoʻī
  • Understanding and Choosing a Line Impedance Tester for Optimal Network Performance
    Understanding and Choosing a Line Impedance Tester for Optimal Network Performance
    In the realm of telecommunications and electrical engineering, maintaining the integrity of transmission lines is paramount. A line impedance tester is a crucial instrument for ensuring optimal signal transmission and preventing costly network disruptions. This article delves into the world of line impedance testing, exploring its importance, applications, types of testers, and what to look for when making a purchase. Ensuring accurate impedance measurements is essential for efficient and reliable network performance. Choosing the right tester can significantly impact troubleshooting speed and the overall quality of your infrastructure. A line impedance tester, also known as a cable impedance analyzer, is a device used to measure the characteristic impedance of coaxial cables, twisted pair cables, and other transmission lines. Impedance, measured in ohms, represents the opposition to the flow of alternating current. Maintaining the correct impedance (typically 50 or 75 ohms) is vital for minimizing signal reflections, ensuring efficient power transfer, and preventing signal degradation. Mismatched impedance can lead to signal loss, ghosting, and reduced network performance. Regular testing helps identify faults and maintain network integrity.
    kikoʻī

Inā makemake ʻoe i kā mākou huahana, hiki iā ʻoe ke koho e waiho i kāu ʻike ma aneʻi, a e hoʻopili koke mākou iā ʻoe.