EnglishIcyongereza

PUSH Electrical PS-3045 High Voltage Insulation Resistance Tester

Imashini ya PS-3045 irwanya ibyuma byifashishwa, bizwi kandi nka megger, ibizamini byo kurwanya insimburangingo ya voltage nyinshi, nibindi, bikoreshwa mugupimisha irwanya insulation. Ifite umurimo wo gupima ingufu za DC, voltage ya AC, igipimo cya DC cyo kwinjiza no kugereranya polarisiyasi.
SHAKA UMURONGO Kuri PDF
Ibisobanuro
Etiquetas
Ibicuruzwa byo kugurisha

 

  1. 1. Igikoresho gifite imiterere idahungabana, itagira umukungugu, hamwe nubushuhe butarimo ubushuhe.
    2. Nibikoresho bisanzwe bikoreshwa kandi byingirakamaro mubitumanaho, ingufu z'amashanyarazi, meteorologiya, ibyumba bya mudasobwa, imirima ya peteroli, imashini zikoresha amashanyarazi no kuyitaho, hamwe ninganda zinganda zikoresha amashanyarazi nkingufu zinganda cyangwa ingufu.
    3. Birakwiriye gupima agaciro kokurwanya ibikoresho bitandukanye byokwirinda hamwe no kurwanya insulanseri, moteri, insinga nibikoresho byamashanyarazi.
    4. Mugihe kimwe, irashobora gusohora ibintu bitandukanye bya voltage zitandukanye kandi ifite imikorere yo guhinduranya intambwe.

 

Ibicuruzwa 

 

1. Umuvuduko wa voltage & nukuri

 

Igikorwa cyo gupima

Urwego rwo gupima

Ukuri

imyanzuro

Umuyoboro wa DC

DC 0.0V ~ 1000V

± 5% rdg ± 3dgt

0.1V

Umuvuduko wa AC

AC 0.0V ~ 750V

± 5% rdg ± 3dgt

0.1V

 

2. Urwego rugezweho & ukuri

 

Igikorwa cyo gupima

Urwego rwo gupima

Ukuri

imyanzuro

Umuyoboro wa DC

1mA-6mA

± 5% rdg ± 2dgt

0.01mA

100uA-1000uA

± 5% rdg ± 2dgt

1uA

10uA-100uA

± 5% rdg ± 2dgt

0.1uA

1uA-10uA

± 5% rdg ± 2dgt

0.01uA

100nA-1000nA

± 5% rdg ± 2dgt

1nA

10nA-100nA

± 10% rdg ± 5dgt

0.1nA

1nA-10nA

± 20% rdg ± 5dgt

0.01nA

100pA-1000pA

± 30% rdg ± 5dgt

1pA

 

3. Urwego rwubushobozi & ukuri

 

Igikorwa cyo gupima

Urwego rwo gupima

Ukuri

imyanzuro

ubushobozi

10uf-50uf

± 10% fs ± 5dgt

0.01uf

1uf-10uf

± 10% fs ± 5dgt

0.01uf

100nf-1000nf

± 10% fs ± 5dgt

1nf

10nf-100nf

± 10% fs ± 5dgt

0.1nf

 

4. Ibisobanuro bya tekiniki

 

Imikorere

Ikizamini cyo kurwanya insulation, ikizamini cya voltage, DC ikizamini, ikizamini cya capacitance

Imiterere shingiro

23 ℃ ± 5 ℃ , munsi ya 75% rh

PS-3045

Ikigereranyo cya voltage

100V 、 250V 、 500V 、 1000V 、 2500V 、 5000V

Urwego rwo kurwanya insulation

0.01MΩ ~ 10TΩ

imyanzuro : 0.01MΩ

PS-3045E

Ikigereranyo cya voltage

250V 、 500V 、 1000V 、 2500V 、 5000V 、 10KV

Urwego rwo kurwanya insulation

0.01MΩ ~ 35TΩ

imyanzuro : 0.01MΩ

PS-3045F

Ikigereranyo cya voltage

500V 、 1000V 、 2500V 、 5000V 、 10KV 、 15KV

Urwego rwo kurwanya insulation

0.01MΩ ~ 50TΩ

imyanzuro : 0.01MΩ

Umuvuduko w'ikizamini (V)

igipimo cya voltage × (1 ± 10%)

Umuyoboro wa DC

0 ~ 1000V

Umwanzuro: 0.1V

Umuyoboro wa AC

0 ~ 750V

Umwanzuro: 0.1V

DC Ibiriho

0.1nA ~ 6mA

Umwanzuro: 0.1nA

Ubushobozi

10nF ~ 50uF

Icyemezo: 10nF

Ibisohoka bigufi-bizunguruka

≥6mA @ 15KV

Igipimo cya Absorption na Igipimo cya Polarisiyasi

Kugira

 

10kv insulation tester

digital insulation resistance tester

hipot and insulation resistance tester

insulation resistance

insulation resistance tester

insulation tester 1000v

motor insulation tester

wire insulation tester

Niba ushimishijwe nibicuruzwa byacu, urashobora guhitamo gusiga amakuru yawe hano, kandi tuzahuza nawe vuba.


Andika ubutumwa bwawe hano hanyuma utwohereze
Bifitanye isano Amakuru
  • Find the Best Loop Impedance Tester for Sale and Ensure Electrical Safety
    Find the Best Loop Impedance Tester for Sale and Ensure Electrical Safety
    When ensuring electrical safety, accurate loop impedance testing is crucial. Whether you’re an electrician, a facilities manager, or a safety inspector, having a reliable loop impedance tester for sale is essential. This article will guide you through the key considerations when purchasing a loop impedance tester, explore the different types available, and highlight the benefits of choosing a high-quality instrument. Understanding the nuances of these testers will help you make an informed decision and ensure compliance with safety regulations.
    Ibisobanuro
  • Comprehensive Guide to Loop Impedance Meter for Electrical Safety
    Comprehensive Guide to Loop Impedance Meter for Electrical Safety
    Ensuring electrical safety is paramount in any installation, and a loop impedance meter is a crucial tool for achieving this. This device measures the total impedance of the earth fault loop, helping to verify that protective devices will operate correctly under fault conditions. In this article, we'll explore what a loop impedance meter is, how it works, its applications, factors influencing measurements, choosing the right meter, and the importance of regular testing. Investing in a quality meter from Push Tester is a step towards safer electrical systems.
    Ibisobanuro
  • Understanding and Choosing a Line Impedance Tester for Optimal Network Performance
    Understanding and Choosing a Line Impedance Tester for Optimal Network Performance
    In the realm of telecommunications and electrical engineering, maintaining the integrity of transmission lines is paramount. A line impedance tester is a crucial instrument for ensuring optimal signal transmission and preventing costly network disruptions. This article delves into the world of line impedance testing, exploring its importance, applications, types of testers, and what to look for when making a purchase. Ensuring accurate impedance measurements is essential for efficient and reliable network performance. Choosing the right tester can significantly impact troubleshooting speed and the overall quality of your infrastructure. A line impedance tester, also known as a cable impedance analyzer, is a device used to measure the characteristic impedance of coaxial cables, twisted pair cables, and other transmission lines. Impedance, measured in ohms, represents the opposition to the flow of alternating current. Maintaining the correct impedance (typically 50 or 75 ohms) is vital for minimizing signal reflections, ensuring efficient power transfer, and preventing signal degradation. Mismatched impedance can lead to signal loss, ghosting, and reduced network performance. Regular testing helps identify faults and maintain network integrity.
    Ibisobanuro

Niba ushimishijwe nibicuruzwa byacu, urashobora guhitamo gusiga amakuru yawe hano, kandi tuzahuza nawe vuba.