PS-2000A Insulation Ola Dielectric Loss and Volume Resistivity Tester

Is e ginealach ùr de mheatair call dielectric ola agus resistivity ola inslithe so-ghiùlain a tha air a dhealbhadh a rèir ASTM D924 agus GB / 5654. insulation liquids. Tha e furasta obrachadh le dàta deuchainn earbsach agus ceart.
DOWNLOAD GU PDF
Mion-fhiosrachadh
Tagaichean
Ro-ràdh puing reic toraidh

 

  1. 1.High fèin-ghluasad, teasachadh, a 'tomhas dielectric call, agus resistivity tomhas urrainn a chrìochnachadh aig àm.
    2. Faodaidh an structar trì seòrsa electrode le inbhe GB/T5654-2007, eadar-dhealachadh eadar dealanan 2mm, cuir às do chomas air seachran agus buaidh aoidionachd air toraidhean deuchainn call dielectric.
    3.Tha an ionnstramaid a 'cleachdadh teasachadh inntrigidh tricead meadhanach, algorithm smachd teothachd PID. Tha na buannachdan aig a ’mhodh teasachaidh seo bho neo-conaltraidh, cupa ola agus bodhaig teasachaidh, astar teasachaidh èideadh, smachd goireasach, smachd teothachd ann an teòthachd taobh a-staigh mearachd raon ro-shuidhichte.
    4.Using teicneòlas adhartach DSP agus FFT gus dèanamh cinnteach à seasmhachd, mionaideachd agus earbsachd an dàta
    5. Taobh a-staigh capacitor àbhaisteach airson an SF6 cosgais trì pòla capacitor, call dielectric agus capacitance an capacitor chan eil buaidh le àrainneachd Teòthachd, Taiseachd, msaa, gus am bi cinnteach gu bheil cruinneas an ionnstramaid an dèidh ùine fhada a chleachdadh.
    6. Sgrion suathaidh dath sgrion mòr, conaltradh fear-inneal goireasach, obrachadh pongail, soilleir.
    7. Le mullach far an bholtaids àrd, cuimhneachan goirid cupa electrode bholtaids àrd, cuir às do chunnartan sàbhailteachd, gus dèanamh cinnteach à obrachadh àbhaisteach sàbhailteachd luchd-obrach agus uidheamachd.
    8. Le gleoc fìor-ùine, ceann-latha deuchainn, faodar ùine a shàbhaladh le toraidhean deuchainn, taisbeanadh, clò-bhualadh; faodaidh uidheamachd an teòthachd àrainneachd a thaisbeanadh, lorg fìor-ùine air an àrainneachd deuchainn.
    9. Faodaidh dàta tomhais stòraidh fèin-ghluasadach, 100 seata de dhàta tomhais a stòradh.
    10. Gnìomh ceartachaidh cupa electrode falamh. Thathas a’ tomhas comas capacitance agus call dielectric a ’chupa electrode falamh gus breithneachadh a dhèanamh air suidheachadh glanaidh is cruinneachaidh a’ chupa electrode falamh. Tha an dàta calibration air a shàbhaladh gu fèin-ghluasadach gus obrachadh a-mach ceart de chomas coimeasach agus resistivity DC.

 

Paramadairean toraidh

 

Paramadair

Clàr-innse

Paramadair

Clàr-innse

tomhas
Raon

Capacitance

5pF - 200pF

Fuasgladh cumhachd

Capacitance

0.01pF

Call dielectric

0.00001 gu 100

Call dielectric

10-5

Resistivity

2.5mm agus 20m

Resistivity

0.001M

Tomhais
cruinneas

Capacitance

0.5%+1PF

Smachd air cruinneas

±0.5 ℃

Call dielectric

±(1% Leughadh+0.0001)

Raon teòthachd

0 ~ 125 ℃

Resistivity

± 10% a’ leughadh

bholtaids AC

AC 0 ~ 2200V

bholtaids DC

DC 0 ~ 600V

Teòthachd àrainneachd

0 ~ 40 ℃

Taiseachd àrainneachdail

<80% RH

Solar cumhachd obrach

AC220V ± 10% (50 ± 1) Hz

Meud

420mm*380mm*420mm

Cumhachd

100W

Cuideam

21Kg (Cupa an-asgaidh)

 

Bhideo

 

dielectric loss factor

dielectric loss meter

dielectric loss tangent

dielectric loss test

insulating oil tester

oil tan delta tester

oil tester

oil tester kit

tan delta tester

transformer oil tester

volume resistivity tester

Ma tha ùidh agad anns na stuthan againn, faodaidh tu roghnachadh d’ fhiosrachadh fhàgail an seo, agus bidh sinn ann an conaltradh riut a dh’ aithghearr.


Sgrìobh do theachdaireachd an seo agus cuir thugainn e
Co-cheangailte Naidheachdan
  • Find the Best Loop Impedance Tester for Sale and Ensure Electrical Safety
    Find the Best Loop Impedance Tester for Sale and Ensure Electrical Safety
    When ensuring electrical safety, accurate loop impedance testing is crucial. Whether you’re an electrician, a facilities manager, or a safety inspector, having a reliable loop impedance tester for sale is essential. This article will guide you through the key considerations when purchasing a loop impedance tester, explore the different types available, and highlight the benefits of choosing a high-quality instrument. Understanding the nuances of these testers will help you make an informed decision and ensure compliance with safety regulations.
    Mion-fhiosrachadh
  • Comprehensive Guide to Loop Impedance Meter for Electrical Safety
    Comprehensive Guide to Loop Impedance Meter for Electrical Safety
    Ensuring electrical safety is paramount in any installation, and a loop impedance meter is a crucial tool for achieving this. This device measures the total impedance of the earth fault loop, helping to verify that protective devices will operate correctly under fault conditions. In this article, we'll explore what a loop impedance meter is, how it works, its applications, factors influencing measurements, choosing the right meter, and the importance of regular testing. Investing in a quality meter from Push Tester is a step towards safer electrical systems.
    Mion-fhiosrachadh
  • Understanding and Choosing a Line Impedance Tester for Optimal Network Performance
    Understanding and Choosing a Line Impedance Tester for Optimal Network Performance
    In the realm of telecommunications and electrical engineering, maintaining the integrity of transmission lines is paramount. A line impedance tester is a crucial instrument for ensuring optimal signal transmission and preventing costly network disruptions. This article delves into the world of line impedance testing, exploring its importance, applications, types of testers, and what to look for when making a purchase. Ensuring accurate impedance measurements is essential for efficient and reliable network performance. Choosing the right tester can significantly impact troubleshooting speed and the overall quality of your infrastructure. A line impedance tester, also known as a cable impedance analyzer, is a device used to measure the characteristic impedance of coaxial cables, twisted pair cables, and other transmission lines. Impedance, measured in ohms, represents the opposition to the flow of alternating current. Maintaining the correct impedance (typically 50 or 75 ohms) is vital for minimizing signal reflections, ensuring efficient power transfer, and preventing signal degradation. Mismatched impedance can lead to signal loss, ghosting, and reduced network performance. Regular testing helps identify faults and maintain network integrity.
    Mion-fhiosrachadh

Ma tha ùidh agad anns na stuthan againn, faodaidh tu roghnachadh d’ fhiosrachadh fhàgail an seo, agus bidh sinn ann an conaltradh riut a dh’ aithghearr.