PS-2000A Idabobo Epo Dielectric Pipadanu Ati Iwọn didun Resistivity

Insulating epo dielectric loss tester / Oil Tan delta tester jẹ iran tuntun ti pipadanu dielectric epo insulating ni kikun laifọwọyi ati mita resistivity ti a ṣe ni ibamu si ASTM D924 ati GB / 5654.O ti lo fun wiwọn ifosiwewe dissipation dielectric ati DC resistivity ti epo idabobo ati awọn miiran insulating olomi. O rọrun lati ṣiṣẹ pẹlu igbẹkẹle ati data idanwo deede.
DOWN fifuye TO PDF
Awọn alaye
Awọn afi
Ọja Ta Point Ifihan

 

  1. 1.High automation, alapapo, wiwọn pipadanu dielectric, ati wiwọn resistivity le pari ni akoko kan.
    2.The mẹta elekiturodu iru be pẹlu ohun GB / T5654-2007 bošewa, inter elekiturodu aye 2mm, le se imukuro stray capacitance ati jijo ipa lori dielectric pipadanu igbeyewo esi.
    3.The irinse nlo alabọde igbohunsafẹfẹ induction alapapo, PID otutu iṣakoso alugoridimu. Ipo alapapo yii ni awọn anfani ti kii ṣe olubasọrọ, ago epo ati ara alapapo, iyara alapapo aṣọ, iṣakoso irọrun, iṣakoso iwọn otutu ni iwọn otutu laarin aṣiṣe tito tẹlẹ.
    4.Using to ti ni ilọsiwaju DSP ati FFT ọna ẹrọ lati rii daju awọn iduroṣinṣin, išedede ati dede ti awọn data
    5. Ti abẹnu boṣewa kapasito fun awọn SF6 gbigba agbara mẹta polu kapasito, dielectric pipadanu ati capacitance ti awọn kapasito ti wa ni ko ni fowo nipasẹ ibaramu otutu, ọriniinitutu, ati be be lo, ki awọn išedede ti awọn irinse lẹhin igba pipẹ lati lo ti wa ni ṣi ẹri.
    6. Iboju ifọwọkan awọ iboju nla, ibaraẹnisọrọ ẹrọ-ẹrọ rọrun, iṣẹ ṣoki, ko o.
    7. Pẹlu awọn ideri si pa awọn ga foliteji, ga foliteji elekiturodu ife kukuru olurannileti, imukuro ailewu ewu, lati rii daju awọn deede isẹ ti aabo ti awọn oniṣẹ ẹrọ ati ẹrọ.
    8. Pẹlu aago akoko gidi, ọjọ idanwo, akoko le wa ni fipamọ pẹlu awọn esi idanwo, ifihan, titẹ; ohun elo le ṣe afihan iwọn otutu ibaramu, wiwa akoko gidi ti agbegbe idanwo naa.
    9. Awọn data wiwọn ipamọ aifọwọyi, le tọju awọn eto 100 ti data wiwọn.
    10. Atunse iṣẹ ti sofo elekiturodu ife. Awọn capacitance ati dielectric pipadanu ifosiwewe ti awọn sofo elekiturodu ife ti wa ni won lati ṣe idajọ ninu ati Nto majemu ti awọn sofo elekiturodu ife. Awọn data isọdọtun ti wa ni fipamọ laifọwọyi lati dẹrọ iṣiro deede ti agbara ibatan ati resistivity DC.

 

Ọja paramita

 

Paramita

Atọka

Paramita

Atọka

odiwọn
Ibiti o

Agbara

5pF~200pF

Agbara ipinnu

Agbara

0.01pF

Dielectric pipadanu

0.00001-100

Dielectric pipadanu

10-5

Resistivity

2.5MΩm~20TΩm

Resistivity

0.001M

Iwọn
išedede

Agbara

0.5% + 1PF

Iṣakoso išedede

± 0.5 ℃

Dielectric pipadanu

± (1% Kika+0.0001)

Iwọn iwọn otutu

0~125℃

Resistivity

± 10% Kika

AC foliteji

AC 0 ~ 2200V

DC foliteji

DC 0 ~ 600V

Ibaramu otutu

0~40℃

Ibaramu ọriniinitutu

80% RH

Ipese agbara ṣiṣẹ

AC220V± 10%(50±1)Hz

Iwọn

420mm * 380mm * 420mm

Agbara

100W

Iwọn

21kg (Ago ọfẹ)

 

Fidio

 

dielectric loss factor

dielectric loss meter

dielectric loss tangent

dielectric loss test

insulating oil tester

oil tan delta tester

oil tester

oil tester kit

tan delta tester

transformer oil tester

volume resistivity tester

Ti o ba nifẹ si awọn ọja wa, o le yan lati fi alaye rẹ silẹ nibi, ati pe a yoo kan si ọ laipẹ.


Kọ ifiranṣẹ rẹ nibi ki o si fi si wa
Jẹmọ Iroyin
  • Low-Temperature Kinematic Viscosity Testing: A Practical Guide
    Low-Temperature Kinematic Viscosity Testing: A Practical Guide
    Explore low-temperature kinematic viscosity testing, its measurement principles, and key equipment selection considerations. Learn how to distinguish capillary testing from rotational viscosity methods and what information to provide when discussing laboratory requirements with Baoding Push Electrical Manufacturing Co., Ltd.
    Ẹ̀kúnrẹ́rẹ́
  • Comprehensive Guide to Insulating Oil BDV Testers for Transformer Maintenance
    Comprehensive Guide to Insulating Oil BDV Testers for Transformer Maintenance
    Learn what an insulating oil BDV tester measures, how breakdown voltage testing supports transformer maintenance, and which features to consider when choosing equipment for your laboratory or maintenance team.
    Ẹ̀kúnrẹ́rẹ́
  • Find the Right Insulating Oil BDV Tester for Reliable Transformer Maintenance
    Find the Right Insulating Oil BDV Tester for Reliable Transformer Maintenance
    Explore how to choose an insulating oil BDV tester for transformer maintenance and laboratory testing. Compare single-cup and multi-cup configurations, key purchasing factors, and testing requirements with PUSH Tester.
    Ẹ̀kúnrẹ́rẹ́

Ti o ba nifẹ si awọn ọja wa, o le yan lati fi alaye rẹ silẹ nibi, ati pe a yoo kan si ọ laipẹ.