English


Afrikaans
Albanian
Amharic
Arabic
Armenian
Azerbaijani
Basque
Belarusian
Bengali
Bosnian
Bulgarian
Catalan
Cebuano
China
China (Taiwan)
Corsican
Croatian
Czech
Danish
Dutch
English
Esperanto
Estonian
Finnish
French
Frisian
Galician
Georgian
German
Greek
Gujarati
Haitian Creole
hausa
hawaiian
Hebrew
Hindi
Miao
Hungarian
Icelandic
igbo
Indonesian
irish
Italian
Japanese
Javanese
Kannada
kazakh
Khmer
Rwandese
Korean
Kurdish
Kyrgyz
Lao
Latin
Latvian
Lithuanian
Luxembourgish
Macedonian
Malgashi
Malay
Malayalam
Maltese
Maori
Marathi
Mongolian
Myanmar
Nepali
Norwegian
Norwegian
Occitan
Pashto
Persian
Polish
Portuguese
Punjabi
Romanian
Russian
Samoan
Scottish Gaelic
Serbian
Sesotho
Shona
Sindhi
Sinhala
Slovak
Slovenian
Somali
Spanish
Sundanese
Swahili
Swedish
Tagalog
Tajik
Tamil
Tatar
Telugu
Thai
Turkish
Turkmen
Ukrainian
Urdu
Uighur
Uzbek
Vietnamese
Welsh
Bantu
Yiddish
Yoruba
Zulu
●Voltage and current six-and-a-half-digit liquid crystal display, higher display accuracy, more accurate experimental results
●128*64 dot matrix liquid crystal display, display data is more intuitive and reading is faster
●Instrument display lock function, especially for more accurate and faster readings in transformer ratio experiments
●485 communication function, experimental results can be uploaded directly or stored in U disk instead of manual recording
●Polarity measurement, automatic measurement of transformer polarity, no need for separate experiments
●Chronograph 0.1mS-999999.9mS LCD display
●The beautiful and elegant PVC panel is used to make the panel more resistant to dirt and wear
●High measurement accuracy 0.5 class
●High power, small size, strong load capacity
●Small size and light weight, the volume is only 30% to 70% of similar products, and it is very convenient to carry.
|
NAME |
PS-DL10High current generator |
|
Environmental group |
It belongs to group III instruments in |
|
Input |
AC 50Hz, 380V |
|
Output |
Single-phase 0-2500.00A AC current; the |
|
The output current is a standard sine wave, the burr is small, which is better than |
|
|
output current mode |
True RMS continuously adjustable |
|
output waveform |
standard sine wave |
|
Output opening voltage |
5V |
|
Current accuracy |
Each current can be adjusted smoothly and continuously, and the |
|
Current stability |
0.1% |
|
Current waveform distortion |
THD 1% |
|
Protection settings |
overcurrent, overvoltage |
|
The current action time of the tested element can be measured, and the locking |
|
|
Timing range |
0. 0001S—9999.9999S, |
|
precision |
0. 0001S |
|
power |
10000VA |