EnglishEnglish

PUSH Electrical PS-JSB01 Transformer Dielectric Loss Analysis Tan Delta Tester

The dielectric loss tester adopts variable frequency power supply technology, single chip microcomputer and modern technology for automatic frequency conversion, analog-to-digital conversion and data operation; It has strong anti-interference ability, fast test speed, high precision, automatic digitization and simple operation; The power supply adopts high-power switching power supply, which can provide a maximum voltage of 10kV; It can automatically filter out 50Hz interference and is suitable for on-site test with large electromagnetic interference such as substation. It is widely used for dielectric loss measurement of transformers, mutual inductors, bushings, capacitors, arresters and other equipment in power industry.
DOWN LOAD TO PDF
Details
Tags
Product Selling Point Introduction

 

  1. Core Description
    The dielectric loss tester adopts variable frequency power supply technology, single chip microcomputer and modern technology for automatic frequency conversion, analog-to-digital conversion and data operation; It has strong anti-interference ability, fast test speed, high precision, automatic digitization and simple operation; The power supply adopts high-power switching power supply, which can provide a maximum voltage of 10kV; It can automatically filter out 50Hz interference and is suitable for on-site test with large electromagnetic interference such as substation. It is widely used for dielectric loss measurement of transformers, mutual inductors, bushings, capacitors, arresters and other equipment in power industry.

  2. Introduction
    1. The instrument adopts Fourier transform digital filtering technology to measure capacitance, dielectric loss and other parameters. The test results have high precision and are easy to realize automatic measurement.
    2. The instrument adopts frequency conversion technology to eliminate 50Hz power frequency interference on site, and can measure reliable data even in the environment of strong electromagnetic interference.
    3. Data storage: it is internally equipped with calendar chip and large capacity memory, which can save the test results at any time, view the historical records at any time, and print out.
    4. Instrument data can be exported through USB flash disk.
    5. Integrated model with standard capacitor and high voltage power supply, which is convenient for field test and reduces field wiring.
    6. It has the function of reverse wiring low-voltage shielding. Under the condition of 220kV CVT bus grounding, the dielectric loss of C11 can be measured without disconnecting 10kV reverse wiring.
    7. It can identify the frequency of external high-voltage power supply from 40Hz to 70Hz, and it is allowed to use power frequency power supply or series resonant power supply for large capacity and high-voltage dielectric loss test.
    8. With CVT test function, it can realize CVT self excitation test, and can set four protection limits of high voltage / current and low voltage / current to ensure personal and equipment safety.
    9. When testing CVT, it can not only automatically test the capacitance and dielectric loss of C1 and C2, but also test the total capacitance and dielectric loss of CVT equipment.
    10. With a thermal printer.
    11. With computer interface. One computer can control 32 instruments, which can be integrated into the comprehensive high voltage test vehicle to realize measurement, data processing and report output.
    12. Grounding protection function, electric shock protection function.

 

Product Parameter 

 

Accuracy

Cx

± (reading) × 1%+1pF)

tg δ

± (reading) × 1%+0.00040)

Anti interference index

frequency conversion anti-interference, which can still achieve the above accuracy under 200% interference

Capacitance range

Internally applied high pressure

3pF~60000pF/10kV 60pF~1 μ F/0.5kV

Externally applied high voltage

3pF~1.5 μ F/10kV 60pF~30 μ F/0.5kV

resolving power

Up to 0.001pf, 4 significant digits

tg δ Range

Unlimited, resolution 0.001%, automatic identification of capacitance, inductance and resistance.

Test current range

10 μ A~5A

Internally applied high pressure

Set voltage range

0.5 ~ 10KV

Maximum output current

200mA

Voltage rise and fall mode

the voltage is set at will. For example, 5123v.

Test frequency

40-70HZ, single frequency set at will. For example, 48.7hz

Automatic double frequency conversion from 50 ± 0.1Hz to 50 ± 10Hz can be set at will.

Automatic double frequency conversion from 60 ± 0.1Hz to 60 ± 10Hz can be set at will.

Frequency accurac

±0.01Hz

Externally applied high voltage

The maximum test current during positive connection is 5a, power frequency or frequency conversion is 40-70HZ

The maximum test current during reverse wiring is 10kV / 5A, power frequency or frequency conversion is 40-70HZ

CVT self excitation low voltage output

output voltage 3 ~ 50V, output current 3 ~ 30A

Measurement time

About 40s, related to the measurement method

Input power supply

180V ~ 270vac, 50Hz ± 1%, mains power or generator power supply

Computer interface

standard RS232 interface, USB flash disk socket (automatic USB flash disk data storage).

Printer

micro thermal printer

ambient temperature

– 10 ℃ ~ 50 ℃

relative humidity

< 90%

Overall dimension

460 × 360× 350mm

instrument weight

28KG

 

Video

 

ac dielectric tester

capacitance and tan delta test of transformer

dc dielectric test

dielectric loss factor

dielectric loss test

dielectric resistance test

dielectric test

dissipation factor dielectric

tan delta meter

tan delta of ct

tan delta of transformer

tan delta system

tan delta test

tan delta test kit

tan delta test set

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.


Write your message here and send it to us
Related News
  • Find the Best Loop Impedance Tester for Sale and Ensure Electrical Safety
    Find the Best Loop Impedance Tester for Sale and Ensure Electrical Safety
    When ensuring electrical safety, accurate loop impedance testing is crucial. Whether you’re an electrician, a facilities manager, or a safety inspector, having a reliable loop impedance tester for sale is essential. This article will guide you through the key considerations when purchasing a loop impedance tester, explore the different types available, and highlight the benefits of choosing a high-quality instrument. Understanding the nuances of these testers will help you make an informed decision and ensure compliance with safety regulations.
    Detail
  • Comprehensive Guide to Loop Impedance Meter for Electrical Safety
    Comprehensive Guide to Loop Impedance Meter for Electrical Safety
    Ensuring electrical safety is paramount in any installation, and a loop impedance meter is a crucial tool for achieving this. This device measures the total impedance of the earth fault loop, helping to verify that protective devices will operate correctly under fault conditions. In this article, we'll explore what a loop impedance meter is, how it works, its applications, factors influencing measurements, choosing the right meter, and the importance of regular testing. Investing in a quality meter from Push Tester is a step towards safer electrical systems.
    Detail
  • Understanding and Choosing a Line Impedance Tester for Optimal Network Performance
    Understanding and Choosing a Line Impedance Tester for Optimal Network Performance
    In the realm of telecommunications and electrical engineering, maintaining the integrity of transmission lines is paramount. A line impedance tester is a crucial instrument for ensuring optimal signal transmission and preventing costly network disruptions. This article delves into the world of line impedance testing, exploring its importance, applications, types of testers, and what to look for when making a purchase. Ensuring accurate impedance measurements is essential for efficient and reliable network performance. Choosing the right tester can significantly impact troubleshooting speed and the overall quality of your infrastructure. A line impedance tester, also known as a cable impedance analyzer, is a device used to measure the characteristic impedance of coaxial cables, twisted pair cables, and other transmission lines. Impedance, measured in ohms, represents the opposition to the flow of alternating current. Maintaining the correct impedance (typically 50 or 75 ohms) is vital for minimizing signal reflections, ensuring efficient power transfer, and preventing signal degradation. Mismatched impedance can lead to signal loss, ghosting, and reduced network performance. Regular testing helps identify faults and maintain network integrity.
    Detail

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.