English


Afrikaans
Albanian
Amharic
Arabic
Armenian
Azerbaijani
Basque
Belarusian
Bengali
Bosnian
Bulgarian
Catalan
Cebuano
China
China (Taiwan)
Corsican
Croatian
Czech
Danish
Dutch
English
Esperanto
Estonian
Finnish
French
Frisian
Galician
Georgian
German
Greek
Gujarati
Haitian Creole
hausa
hawaiian
Hebrew
Hindi
Miao
Hungarian
Icelandic
igbo
Indonesian
irish
Italian
Japanese
Javanese
Kannada
kazakh
Khmer
Rwandese
Korean
Kurdish
Kyrgyz
Lao
Latin
Latvian
Lithuanian
Luxembourgish
Macedonian
Malgashi
Malay
Malayalam
Maltese
Maori
Marathi
Mongolian
Myanmar
Nepali
Norwegian
Norwegian
Occitan
Pashto
Persian
Polish
Portuguese
Punjabi
Romanian
Russian
Samoan
Scottish Gaelic
Serbian
Sesotho
Shona
Sindhi
Sinhala
Slovak
Slovenian
Somali
Spanish
Sundanese
Swahili
Swedish
Tagalog
Tajik
Tamil
Tatar
Telugu
Thai
Turkish
Turkmen
Ukrainian
Urdu
Uighur
Uzbek
Vietnamese
Welsh
Bantu
Yiddish
Yoruba
Zulu
Core Description
The instrument has standard four phase voltage and three-phase current output (six phase voltage and six phase current output). It can not only test various traditional relays and protection devices, but also test various modern microcomputer protection, especially for transformer differential power protection and standby automatic switching device. The test is more convenient and perfect.
|
3*20A |
|||
|
Single phase current output (effective value) |
0 — 20A / phase, |
accuracy |
0.2% ±5mA |
|
Three phase parallel output (effective value) |
0 — 60A / three-phase in-phase parallel output |
||
|
Allowable working value of phase current for a long time (effective value) |
10A |
||
|
Maximum output power of each phase |
200va |
||
|
Maximum output power of three-phase parallel current |
600VA |
||
|
Maximum allowable working time of three parallel current output |
30s |
||
|
Frequency range |
0 — 1000Hz |
accuracy |
0.01Hz |
|
Harmonic frequency |
2-20 times |
||
|
Phase |
0 — 360 ° |
accuracy |
0.1 ° |
|
3*30A |
|||
|
Single phase current output (effective value) |
0 — 30A / phase, |
accuracy |
0.2% ±5mA |
|
Three phase parallel output (effective value) |
0 — 90a / three-phase in-phase parallel output |
||
|
Allowable working value of phase current for a long time (effective value) |
10A |
||
|
Maximum output power of each phase |
300VA |
||
|
Maximum output power of three-phase parallel current |
800VA |
||
|
Maximum allowable working time of three parallel current output |
30s |
||
|
Frequency range |
0 — 1000Hz |
accuracy |
0.01Hz |
|
Harmonic frequency |
2-20 times |
||
|
Phase |
0 — 360 ° |
accuracy |
0.1 ° |
|
3*30A |
|||
|
Single phase current output (effective value) |
0 — 40A / phase |
accuracy |
0.2% ±5mA |
|
Three phase parallel output (effective value) |
0 — 120a / three-phase in-phase parallel output |
||
|
Allowable working value of phase current for a long time (effective value) |
10A |
||
|
Maximum output power of each phase |
420va |
||
|
Maximum output power of three-phase parallel current |
1000VA |
||
|
Maximum allowable working time of three parallel current output |
10s |
||
|
Frequency range |
0 — 1000Hz |
accuracy |
0.01Hz |
|
Harmonic frequency |
2-20 times |
||
|
Phase |
0 — 360 ° |
accuracy |
0.1 ° |
|
6*20A |
|||
|
Single phase current output (effective value) |
0 — 20A / phase |
accuracy |
0.2% ±5mA |
|
Three phase parallel output (effective value) |
0 — 120a / six same phase parallel output |
||
|
Allowable working value of phase current for a long time (effective value) |
10A |
||
|
Maximum output power of each phase |
200va |
||
|
Maximum output power of three-phase parallel current |
800VA |
||
|
Maximum allowable working time of three parallel current output |
30s |
||
|
Frequency range |
0 — 1000Hz |
accuracy |
0.01Hz |
|
Harmonic frequency |
2-20 times |
||
|
Phase |
0 — 360 ° |
accuracy |
0.1 ° |
|
6*30A |
|||
|
Single phase current output (effective value) |
0 — 30A / phase |
accuracy |
0.2% ±5mA |
|
Three phase parallel output (effective value) |
0 — 180A / six same phase parallel output |
||
|
Allowable working value of phase current for a long time (effective value) |
10A |
||
|
Maximum output power of each phase |
300VA |
||
|
Maximum output power of three-phase parallel current |
1000VA |
||
|
Maximum allowable working time of three parallel current output |
30s |
||
|
Frequency range |
0 — 1000Hz |
accuracy |
0.01Hz |
|
Harmonic frequency |
2-20 times |
||
|
Phase |
0 — 360 ° |
accuracy |
0.1 ° |
DC current source
|
DC current output 0 – ± 10A / phase, accuracy |
0.2% ±5mA |
AC Voltage Source
|
Single phase voltage output |
(effective value) 0 — 125V / phase |
accuracy |
0.2% ±5mV |
|
Line voltage output (effective value) |
0 — 250V |
||
|
Phase voltage / line voltage output power |
75va / 100VA |
||
|
Frequency range |
0 — 1000Hz |
accuracy |
0.001Hz |
|
Harmonic frequency |
2-20 times |
||
|
Phase |
0 — 360 ° |
accuracy |
0.1 ° |
DC voltage source
|
Single phase voltage output amplitude |
0 — ± 150V |
accuracy |
0.2% ±5mV |
|
Line voltage output amplitude |
0 — ± 300V |
||
|
Phase voltage / line voltage output power |
90va / 180va |
||
Switching value terminal
|
Switching value input terminal |
8 pairs |
|
Empty contact |
1 — 20mA, 24V, internal active output of the device |
|
Potential reversal |
passive contact:low resistance short circuit signal |
|
Active contact |
0-250V DC |
|
Switching value output terminal |
4 pairs, empty contact, breaking capacity:110V / 2a, 220V / 1A |
Other
|
Time range |
1ms — 9999s, measurement accuracy 1ms |
|
Unit volume and weight |
410 x 190 x 420mm3, about 18kg |
|
Power Supply |
AC220V±10%,50Hz,10A |